Literature DB >> 11585113

In vitro kinetic evaluation of titanium alloy biodegradation.

C Sedarat1, M F Harmand, A Naji, H Nowzari.   

Abstract

The present controlled in vitro experiment evaluated the dissolution kinetics of titanium (Ti), aluminum (Al) and vanadium (V). Titanium alloy (Ti90Al6V4) dental implants were inserted in 1.8 ml sterile tubes, containing equal volumes of NaCl 0.9% (w/v) and human serum. Metallic elements released by the atomic process of corrosion were measured at pH 7.2 and 37 C by atomic absorption spectrophotometer at 1, 3, 6, 9, 15, 21, 27, 33, 42, 51, 60, 69, 78, 87 and 96 days. Ti dissolution averaged 16+/-5 ng/cm2/day and 1565 ng/cm2 over the experimental period. Al dissolution was stable at 9+/-5 ng/cm2/day and averaged 945 ng/cm2 over the 96-day period. V dissolution was stable at 0.15+/-0.18 ng/cm2/day after the sixth day of incubation and averaged 42 ng/cm2 over the 96-day period. Major disparities in atomic dissolution were detected among implants. No local or systemic reaction to titanium has been documented. In contrast, 4% toxic V and 6% Al may suffice to elicit local and systemic reactions or inhibit cellular proliferation and differentiation.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11585113     DOI: 10.1034/j.1600-0765.2001.360501.x

Source DB:  PubMed          Journal:  J Periodontal Res        ISSN: 0022-3484            Impact factor:   4.419


  6 in total

1.  Miniscrews for orthodontic anchorage: nanoscale chemical surface analyses.

Authors:  Justin Silverstein; Osmar Barreto; Rodrigo França
Journal:  Eur J Orthod       Date:  2015-03-13       Impact factor: 3.075

2.  Long-term durability of orthodontic mini-implants.

Authors:  Mona Aly Abbassy; Ahmed Samir Bakry; Khalid Hashim Zawawi; Ali Habib Hassan
Journal:  Odontology       Date:  2017-08-24       Impact factor: 2.634

Review 3.  Are clinical findings of systemic titanium dispersion following implantation explained by available in vitro evidence? An evidence-based analysis.

Authors:  Justin Paul Curtin; Minji Wang
Journal:  J Biol Inorg Chem       Date:  2017-05-17       Impact factor: 3.358

4.  Assessment of the genetic risks of a metallic alloy used in medical implants.

Authors:  Cristiano C Gomes; Leonardo M Moreira; Vanessa J S V Santos; Alfeu S Ramos; Juliana P Lyon; Cristina P Soares; Fabio V Santos
Journal:  Genet Mol Biol       Date:  2011-03-01       Impact factor: 1.771

5.  Zirconia implants and peek restorations for the replacement of upper molars.

Authors:  José María Parmigiani-Izquierdo; María Eugenia Cabaña-Muñoz; José Joaquín Merino; Arturo Sánchez-Pérez
Journal:  Int J Implant Dent       Date:  2017-02-20

6.  A Literature Review Study on Atomic Ions Dissolution of Titanium and Its Alloys in Implant Dentistry.

Authors:  Sammy Noumbissi; Antonio Scarano; Saurabh Gupta
Journal:  Materials (Basel)       Date:  2019-01-24       Impact factor: 3.623

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.