Literature DB >> 11579400

Power Doppler sonography of the kidney: effect of Valsalva's maneuver.

R Takano1, Y Ando, N Taniguchi, K Itoh, Y Asano.   

Abstract

PURPOSE: It has been reported that an intra-abdominal pressure (IAP) above 15 mm Hg may cause oliguria and that an IAP above 25 mm Hg may cause anuria. Because Valsalva's maneuver yields an IAP exceeding 180 mm Hg, it is presumed to affect renal perfusion. We evaluated the ability of power Doppler sonography to depict the changes in renal blood flow during Valsalva's maneuver.
METHODS: Seven healthy men aged 21-24 years and 1 50-year-old man with massive ascites participated in the study. With each healthy subject lying in a supine position, longitudinal power Doppler sonograms of the kidney were obtained and analyzed semiquantitatively during Valsalva's maneuver. Also, in the patient with massive ascites, power Doppler sonography was performed before and after paracentesis.
RESULTS: Along with an increase in IAP, monitored as expiratory pressure during Valsalva's maneuver, power Doppler signals decreased as indicated by both visual impression and computer scores. In the patient with massive ascites, signal intensity increased after paracentesis.
CONCLUSIONS: Our results demonstrated that an increase in IAP within the physiologic range affects renal perfusion and that power Doppler sonography depicts semiquantitatively the change in renal blood flow. Copyright 2001 John Wiley & Sons, Inc. J Clin Ultra- 29:384-388, 2001.

Entities:  

Mesh:

Year:  2001        PMID: 11579400     DOI: 10.1002/jcu.1053

Source DB:  PubMed          Journal:  J Clin Ultrasound        ISSN: 0091-2751            Impact factor:   0.910


  6 in total

1.  [A new method for standardized diagnosis following renal transplantation. Ultrasound with contrast enhancement].

Authors:  T Fischer; V Ebeling; M Giessing; M Mühler; S Filimonow; J Dieckhöfer; A Lembcke; J Rudolph; S Morgera; K Budde; B Hamm; A Thomas
Journal:  Urologe A       Date:  2006-01       Impact factor: 0.639

2.  Measurement of renal blood flow in human subjects using the ultrasound velocity profiling technique.

Authors:  Ryuichi Takano; Nobuyuki Taniguchi; Kouichi Itoh; Eiji Kusano
Journal:  J Med Ultrason (2001)       Date:  2006-06       Impact factor: 1.314

3.  Haemodynamics Imaging of Swine Segmental Kidney Artery Using Duplex Doppler Technique.

Authors:  Roman Aleksiewicz; Krzysztof Lutnicki; Marcin Bojarski; Ilona Al-Mutari; Aneta Bocheńska
Journal:  J Vet Res       Date:  2019-06-12       Impact factor: 1.744

4.  Renal Resistive Index Is Associated With Inactive Matrix Gla (γ-Carboxyglutamate) Protein in an Adult Population-Based Study.

Authors:  David A Jaques; Edward Pivin; Menno Pruijm; Daniel Ackermann; Idris Guessous; Georg Ehret; Fang-Fei Wei; Jan A Staessen; Antoinette Pechère-Bertschi; Cees Vermeer; Bruno Vogt; Michel Burnier; Pierre-Yves Martin; Murielle Bochud; Belen Ponte
Journal:  J Am Heart Assoc       Date:  2019-09-12       Impact factor: 5.501

5.  Early Sonographic Evaluation of Intrarenal Arterial Resistive Index and Long-term Renal Function in Renal Transplant Recipients in South Western Nigeria.

Authors:  Ajana George Madubueze
Journal:  J Med Ultrasound       Date:  2020-03-05

Review 6.  Ultrasonographic features of kidney transplants and their complications: an imaging review.

Authors:  Chrysafoula Kolofousi; Konstantinos Stefanidis; Demosthenes D Cokkinos; Dimitrios Karakitsos; Eleni Antypa; Ploutarhos Piperopoulos
Journal:  ISRN Radiol       Date:  2012-12-02
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.