Literature DB >> 11575798

An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications.

M L Chabinyc1, D T Chiu, J C McDonald, A D Stroock, J F Christian, A M Karger, G M Whitesides.   

Abstract

This paper describes a prototype of an integrated fluorescence detection system that uses a microavalanche photodiode (microAPD) as the photodetector for microfluidic devices fabricated in poly(dimethylsiloxane) (PDMS). The prototype device consisted of a reusable detection system and a disposable microfluidic system that was fabricated using rapid prototyping. The first step of the procedure was the fabrication of microfluidic channels in PDMS and the encapsulation of a multimode optical fiber (100-microm core diameter) in the PDMS; the tip of the fiber was placed next to the side wall of one of the channels. The optical fiber was used to couple light into the microchannel for the excitation of fluorescent analytes. The photodetector, a prototype solid-state microAPD array, was embedded in a thick slab (1 cm) of PDMS. A thin (80 microm) colored polycarbonate filter was placed on the top of the embedded microAPD to absorb scattered excitation light before it reached the detector. The microAPD was placed below the microchannel and orthogonal to the axis of the optical fiber. The close proximity (approximately 200 microm) of the microAPD to the microchannel made it unnecessary to incorporate transfer optics; the pixel size of the microAPD (30 microm) matched the dimensions of the channels (50 microm). A blue light-emitting diode was used for fluorescence excitation. The microAPD was operated in Geiger mode to detect the fluorescence. The detection limit of the prototype (approximately 25 nM) was determined by finding the minimum detectable concentration of a solution of fluorescein. The device was used to detect the separation of a mixture of proteins and small molecules by capillary electrophoresis; the separation illustrated the suitability of this integrated fluorescence detection system for bioanalytical applications.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11575798     DOI: 10.1021/ac010423z

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  27 in total

1.  Design and development of a field-deployable single-molecule detector (SMD) for the analysis of molecular markers.

Authors:  Jason M Emory; Zhiyong Peng; Brandon Young; Mateusz L Hupert; Arnold Rousselet; Donald Patterson; Brad Ellison; Steven A Soper
Journal:  Analyst       Date:  2011-10-18       Impact factor: 4.616

2.  Microfluidic three-dimensional hydrodynamic flow focusing for the rapid protein concentration analysis.

Authors:  Sungmin Hong; Pei-Hsiang Tsou; Chao-Kai Chou; Hirohito Yamaguchi; Chin B Su; Mien-Chie Hung; Jun Kameoka
Journal:  Biomicrofluidics       Date:  2012-06-20       Impact factor: 2.800

3.  Review Article: Recent advancements in optofluidic flow cytometer.

Authors:  Sung Hwan Cho; Jessica M Godin; Chun-Hao Chen; Wen Qiao; Hosuk Lee; Yu-Hwa Lo
Journal:  Biomicrofluidics       Date:  2010-12-30       Impact factor: 2.800

4.  Development of flow through dielectrophoresis microfluidic chips for biofuel production: Sorting and detection of microalgae with different lipid contents.

Authors:  Yu-Luen Deng; Mei-Yi Kuo; Yi-Je Juang
Journal:  Biomicrofluidics       Date:  2014-12-09       Impact factor: 2.800

5.  Sub-nanomolar detection of thrombin activity on a microfluidic chip.

Authors:  Nam Cao Hoai Le; Murat Gel; Yonggang Zhu; Jian Wang; Helen Dacres; Alisha Anderson; Stephen C Trowell
Journal:  Biomicrofluidics       Date:  2014-12-01       Impact factor: 2.800

6.  Compact and modular multicolour fluorescence detector for droplet microfluidics.

Authors:  Russell H Cole; Niek de Lange; Zev J Gartner; Adam R Abate
Journal:  Lab Chip       Date:  2015-06-02       Impact factor: 6.799

7.  Platelet-derived growth factors-BB and fibroblast growth factors-base induced proliferation of Schwann cells in a 3D environment.

Authors:  Huajun Jiang; Wei Qu; Yuancheng Li; Weiliang Zhong; Weiguo Zhang
Journal:  Neurochem Res       Date:  2012-11-24       Impact factor: 3.996

8.  Integrated microfluidic and imaging platform for a kinase activity radioassay to analyze minute patient cancer samples.

Authors:  Cong Fang; Yanju Wang; Nam T Vu; Wei-Yu Lin; Yao-Te Hsieh; Liudmilla Rubbi; Michael E Phelps; Markus Müschen; Yong-Mi Kim; Arion F Chatziioannou; Hsian-Rong Tseng; Thomas G Graeber
Journal:  Cancer Res       Date:  2010-09-13       Impact factor: 12.701

9.  Generation of living cell arrays for atomic force microscopy studies.

Authors:  Cécile Formosa; Flavien Pillet; Marion Schiavone; Raphaël E Duval; Laurence Ressier; Etienne Dague
Journal:  Nat Protoc       Date:  2014-12-31       Impact factor: 13.491

10.  Electrochemical and optical detectors for capillary and chip separations.

Authors:  Xiaomi Xu; Ling Li; Stephen G Weber
Journal:  Trends Analyt Chem       Date:  2007-01       Impact factor: 12.296

View more