Optimized gating scheme for rapid lifetime determinations of single-exponential luminescence lifetimes.

S P Chan1, Z J Fuller, J N Demas, B A DeGraff.   

Abstract

The rapid lifetime method (RLD) for determining excited-state lifetimes uses the ratio of the areas under two regions of the decay. To get good precision with the standard method, prior knowledge of the lifetime is essential to selecting the integration regions. As will be shown, the usual method of selecting integration regions is far from optimal. An optimal gating scheme that is more precise and much more forgiving in the selection of integration region than any of the prior methods will be shown. Monte Carlo simulations were performed to determine the optimal gating. Experimental data was used to confirm the capabilities of the optimized RLD. The speed of the optimal RLD is similar to the standard RLD but without the necessity of matching the integration interval to the lifetime for precise results.

Year:  2001        PMID: 11575797     DOI: 10.1021/ac0102361

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

1.  A microwell array device capable of measuring single-cell oxygen consumption rates.

Authors:  Timothy W Molter; Sarah C McQuaide; Martin T Suchorolski; Tim J Strovas; Lloyd W Burgess; Deirdre R Meldrum; Mary E Lidstrom
Journal:  Sens Actuators B Chem       Date:  2009-01-15       Impact factor: 7.460

2.  Temperature Compensation of Oxygen Sensing Films Utilizing a Dynamic Dual Lifetime Calculation Technique.

Authors:  Bradley B Collier; Michael J McShane
Journal:  IEEE Sens J       Date:  2014-03-14       Impact factor: 3.301

3.  Time-domain fluorescence lifetime imaging techniques suitable for solid-state imaging sensor arrays.

Authors:  David Day-Uei Li; Simon Ameer-Beg; Jochen Arlt; David Tyndall; Richard Walker; Daniel R Matthews; Viput Visitkul; Justin Richardson; Robert K Henderson
Journal:  Sensors (Basel)       Date:  2012-05-02       Impact factor: 3.576

4.  Maximizing the biochemical resolving power of fluorescence microscopy.

Authors:  Alessandro Esposito; Marina Popleteeva; Ashok R Venkitaraman
Journal:  PLoS One       Date:  2013-10-28       Impact factor: 3.240

5.  A 72 × 60 Angle-Sensitive SPAD Imaging Array for Lens-less FLIM.

Authors:  Changhyuk Lee; Ben Johnson; TaeSung Jung; Alyosha Molnar
Journal:  Sensors (Basel)       Date:  2016-09-02       Impact factor: 3.576

6.  Can we use rapid lifetime determination for fast, fluorescence lifetime based, metabolic imaging? Precision and accuracy of double-exponential decay measurements with low total counts.

Authors:  Susana Figueiredo Silva; José Paulo Domingues; António Miguel Morgado
Journal:  PLoS One       Date:  2019-05-14       Impact factor: 3.240

7.  Optimal parameters in variable-velocity scanning luminescence lifetime microscopy.

Authors:  Zdeněk Petrášek; Juan M Bolivar; Bernd Nidetzky
Journal:  Microsc Res Tech       Date:  2020-07-28       Impact factor: 2.769