Literature DB >> 11565105

A high pressure matrix-assisted laser desorption/ionization Fourier transform mass spectrometry ion source for thermal stabilization of labile biomolecules.

P B O'Connor1, C E Costello.   

Abstract

A high pressure matrix-assisted laser desorption/ionization (MALDI) Fourier transform mass spectrometry (FTMS) ion source was designed and tested. With this design, pressure is pulsed to an estimated 1-10 mbar in the region of the MALDI sample during desorption with the result of significantly decreased fragmentation compared to similar systems operating with pressures of <0.1 mbar. The thermal stabilization of vibrationally excited ions under these conditions is shown with small peptides desorbed from the "hot" matrix alpha-cyano-4-hydroxycinnamic acid, and with the highly labile oxidized beta-chain of insulin. Fragile gangliosides with several sialic acid residues are desorbed under high pressure and remain intact without the typical losses of sialic acid, and a protein standard, ubiquitin (8565.64 Da), is desorbed with minimal dehydration. Under high pressure collisional cooling conditions, non-covalent matrix adduction to the molecular ions becomes prominent, but with the trapped ions in an FT mass spectrometer, the ions can be mildly activated to detach the matrix adducts. The new source, additionally, generates significant levels of the multiply charged ions which are commonly seen in MALDI-TOFMS, but are rarely observed in MALDI-FTMS. This effect is more likely due to the elimination of a mass filtering effect in the previous FTMS ion source than to collisional cooling of the ions. Copyright 2001 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11565105     DOI: 10.1002/rcm.447

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  36 in total

1.  In-source H/D exchange and ion-molecule reactions using matrix assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry with pulsed collision and reaction gases.

Authors:  Matthias Witt; Jens Fuchser; Gökhan Baykut
Journal:  J Am Soc Mass Spectrom       Date:  2002-04       Impact factor: 3.109

2.  A high voltage RF oscillator for driving multipole ion guides.

Authors:  Peter B O'Connor; Catherine E Costello; William E Earle
Journal:  J Am Soc Mass Spectrom       Date:  2002-12       Impact factor: 3.109

3.  A high pressure matrix-assisted laser desorption ion source for Fourier transform mass spectrometry designed to accommodate large targets with diverse surfaces.

Authors:  Peter B O'Connor; Bogdan A Budnik; Vera B Ivleva; Parminder Kaur; Susanne C Moyer; Jason L Pittman; Catherine E Costello
Journal:  J Am Soc Mass Spectrom       Date:  2004-01       Impact factor: 3.109

4.  Fourier transform ion cyclotron resonance mass spectrometry with NanoLC/microelectrospray ionization and matrix-assisted laser desorption/ionization: analytical performance in peptide mass fingerprint analysis.

Authors:  Matthias Witt; Jens Fuchser; Gökhan Baykut
Journal:  J Am Soc Mass Spectrom       Date:  2003-06       Impact factor: 3.109

5.  Compelling advantages of negative ion mode detection in high-mass MALDI-MS for homomeric protein complexes.

Authors:  Stefanie Mädler; Konstantin Barylyuk; Elisabetta Boeri Erba; Robert J Nieckarz; Renato Zenobi
Journal:  J Am Soc Mass Spectrom       Date:  2011-12-01       Impact factor: 3.109

6.  Direct laser desorption ionization of endogenous and exogenous compounds from insect cuticles: practical and methodologic aspects.

Authors:  Joanne Y Yew; Jens Soltwisch; Alexander Pirkl; Klaus Dreisewerd
Journal:  J Am Soc Mass Spectrom       Date:  2011-04-19       Impact factor: 3.109

7.  Atmospheric pressure MALDI-FTMS of normal and chemically modified RNA.

Authors:  Katherine A Kellersberger; Eizadora T Yu; Samuel I Merenbloom; Daniele Fabris
Journal:  J Am Soc Mass Spectrom       Date:  2005-02       Impact factor: 3.109

Review 8.  Accurate mass measurements in proteomics.

Authors:  Tao Liu; Mikhail E Belov; Navdeep Jaitly; Wei-Jun Qian; Richard D Smith
Journal:  Chem Rev       Date:  2007-07-25       Impact factor: 60.622

9.  Development of a dielectric barrier discharge ion source for ambient mass spectrometry.

Authors:  Na Na; Mengxia Zhao; Sichun Zhang; Chengdui Yang; Xinrong Zhang
Journal:  J Am Soc Mass Spectrom       Date:  2007-08-02       Impact factor: 3.109

10.  Mass spectrometric detection of multiple extended series of neutral highly fucosylated N-acetyllactosamine oligosaccharides in human milk.

Authors:  Anja Pfenninger; Shiu-Yung Chan; Michael Karas; Berndt Finke; Bernd Stahl; Catherine E Costello
Journal:  Int J Mass Spectrom       Date:  2008-09-16       Impact factor: 1.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.