D F Kelly1, R J Oskouian, I Fineman. 1. Division of Neurosurgery, University of California at Los Angeles Medical Center, Los Angeles, CA 90095-7039, USA. dkelly@mednet.ucla.edu
Abstract
OBJECTIVE: Repair of a cerebrospinal fluid (CSF) leak created at the time of transsphenoidal surgery typically involves placement of a fat, fascial, or muscle graft and sellar floor reconstruction. In this report, a simplified repair for small, "weeping" CSF leaks using collagen sponge is described. METHODS: All patients underwent an endonasal transsphenoidal procedure using the operating microscope. At the completion of tumor removal, if a small CSF leak was noted but no obvious large arachnoidal defect was present, a piece of collagen sponge was fashioned to cover the exposed diaphragma sellae. Titanium mesh was then wedged into the intrasellar, extradural space and a larger piece of collagen was placed over the reconstructed sellar floor. Nasal packing was removed within 24 hours. RESULTS: During an 18-month period, 62 consecutive transsphenoidal procedures were performed for tumor removal. Of 20 patients with a small CSF leak (18 pituitary adenomas, 1 Rathke's cleft cyst, and 1 chordoma), all had successful repair with collagen sponge. At follow-up examinations at 1 to 18 months, no patient had required a lumbar drain or had developed meningitis. One other patient had a large intraoperative arachnoidal defect that was unsuccessfully repaired with the collagen sponge technique; in this patient, a second operation was required with a fat graft, sellar floor reconstruction, and lumbar drainage. CONCLUSION: A simplified repair of small CSF leaks after transsphenoidal surgery using a two-layered collagen sponge technique with sellar floor reinforcement is thought to be safe and effective and obviates the need for tissue grafts, fibrin glue, or lumbar drain placement.
OBJECTIVE: Repair of a cerebrospinal fluid (CSF) leak created at the time of transsphenoidal surgery typically involves placement of a fat, fascial, or muscle graft and sellar floor reconstruction. In this report, a simplified repair for small, "weeping" CSF leaks using collagen sponge is described. METHODS: All patients underwent an endonasal transsphenoidal procedure using the operating microscope. At the completion of tumor removal, if a small CSF leak was noted but no obvious large arachnoidal defect was present, a piece of collagen sponge was fashioned to cover the exposed diaphragma sellae. Titanium mesh was then wedged into the intrasellar, extradural space and a larger piece of collagen was placed over the reconstructed sellar floor. Nasal packing was removed within 24 hours. RESULTS: During an 18-month period, 62 consecutive transsphenoidal procedures were performed for tumor removal. Of 20 patients with a small CSF leak (18 pituitary adenomas, 1 Rathke's cleft cyst, and 1 chordoma), all had successful repair with collagen sponge. At follow-up examinations at 1 to 18 months, no patient had required a lumbar drain or had developed meningitis. One other patient had a large intraoperative arachnoidal defect that was unsuccessfully repaired with the collagen sponge technique; in this patient, a second operation was required with a fat graft, sellar floor reconstruction, and lumbar drainage. CONCLUSION: A simplified repair of small CSF leaks after transsphenoidal surgery using a two-layered collagen sponge technique with sellar floor reinforcement is thought to be safe and effective and obviates the need for tissue grafts, fibrin glue, or lumbar drain placement.
Authors: M O van Aken; R A Feelders; S de Marie; J H van de Berge; A H G Dallenga; E J Delwel; R M L Poublon; J A Romijn; A J van der Lely; S W J Lamberts; W W de Herder Journal: Pituitary Date: 2004 Impact factor: 4.107
Authors: Edward C Kuan; Frederick Yoo; Pratik B Patel; Brooke M Su; Marvin Bergsneider; Marilene B Wang Journal: J Neurol Surg B Skull Base Date: 2017-08-28