Multidimensional osteodistraction for correction of implant malposition in edentulous segments.

W Zechner1, T Bernhart, K Zauza, A Celar, G Watzek.   

Abstract

This study examined multidimensional osteodistraction as a treatment method for correction of implant malposition and as an alternative to augmentation procedures. The prosthetically unfavourable implant positions were due to growth-related implant malposition (in the context of treatment of young patients with oligodontia) or primary bone-driven implant insertions. The radiographical and clinical findings obtained with this osteodistraction technique are presented and discussed. A tooth-supported osteodistractor for multidimensional distraction with custom-fabricated distraction abutments was used for treatment of 8 patients with a total of 9 maxillary and mandibular edentulous segments including single-tooth gaps. All patients underwent an osteotomy at a minimum distance of 1 mm from the implant surface. Following primary wound healing, distraction was carried out by 1 mm in vertical direction and 0.5 mm in the demanded transverse direction daily until the prosthetically optimized position was achieved. During and after the 12-week retention phase, the patients were evaluated clinically and radiographically. Multidimensional osteodistraction was carried out successfully in all 8 patients. The distraction distances were 3 to 11 mm in vertical direction and a maximum of 5 mm in buccolingual/buccopalatal direction. The malpositioned implants were brought into a prosthetically optimized position in all cases. The results of this study show that this multidimensional osteodistraction technique allows both augmentation of edentulous segments with a clearly compromised implant host site and correction of unfavourable implant positions.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11564115     DOI: 10.1034/j.1600-0501.2001.120515.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  2 in total

1.  Accuracy of half-guided implant placement with machine-driven or manual insertion: a prospective, randomized clinical study.

Authors:  Kristof Orban; Endre Varga; Peter Windisch; Gabor Braunitzer; Balint Molnar
Journal:  Clin Oral Investig       Date:  2021-08-16       Impact factor: 3.606

2.  Segmental osteotomy for mobilization of dental implant.

Authors:  Sergio Olate; Benjamin Weber; Alvaro Marín
Journal:  J Periodontal Implant Sci       Date:  2013-10-29       Impact factor: 2.614