Literature DB >> 1155338

Comparison of angiographic and postmortem findings in patients with coronary artery disease.

J N Schwartz, Y Kong, D B Hackel, A G Bartel.   

Abstract

The accuracy of coronary cineangiography in predicting the degree of stenosis in coronary arteries was evaluated by comparing autopsy and premortem cineangiographic findings in 25 patients. Coronary cineangiograms and autopsy specimens were reviewed independently by two cardiologists and two pathologists. Identical diagrams dividing the cononary arteries into 12 segments were used by both groups to record the location and degree of stenosis observed. Cineangiographic findings were in agreement with pathologic findings (less than 25 percent difference in cross-sectional luminal area) in 178 (79 percent) of the 226 segments examined, but overestimated the degree of stenosis in 13 (6 percent) and underestimated it in 34 (15 percent). Thus, cineangiography appears to be a reliable tool in evaluating coronary artery disease. When diagnostic errors are made, they are usually underestimations of the degree of disease; common causes of error are circumferential stenosis, eccentric lesions, obstruction of view by artifical valves and poor opacification due to severe proximal stenosis.

Entities:  

Mesh:

Year:  1975        PMID: 1155338     DOI: 10.1016/0002-9149(75)90522-6

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  20 in total

1.  Comparison of digital and cine coronary arteriography.

Authors:  J C Gurley; S E Nissen
Journal:  Int J Card Imaging       Date:  1990

Review 2.  The use of computer-assisted diagnosis in cardiac-perfusion nuclear medicine studies: a review.

Authors:  F L Datz; F V Gabor; P E Christian; G T Gullberg; C E Menzel; K A Morton
Journal:  J Digit Imaging       Date:  1992-11       Impact factor: 4.056

Review 3.  [Progression and regression of atherosclerotic plaques. New results based on intracoronary ultrasound].

Authors:  Raimund Erbel
Journal:  Herz       Date:  2015-09       Impact factor: 1.443

4.  Features of the angiographic evaluation of the INTACT study. International Nifedipine Trial on Antiatherosclerotic Therapy.

Authors:  S Jost; J Deckers; W Rafflenbeul; H Hecker; U Nellessen; B Wiese; P G Hugenholtz; P R Lichtlen
Journal:  Cardiovasc Drugs Ther       Date:  1990-08       Impact factor: 3.727

5.  Application of intraluminal ultrasound imaging to vascular stenting.

Authors:  M J Slepian
Journal:  Int J Card Imaging       Date:  1991

6.  Mechanisms of progression in native coronary artery disease: role of healed plaque disruption.

Authors:  J Mann; M J Davies
Journal:  Heart       Date:  1999-09       Impact factor: 5.994

7.  Prediction of severe coronary artery disease by combined rest and exercise radionuclide angiocardiography and tomographic perfusion imaging with technetium 99m-labeled sestamibi: a comparison with clinical and electrocardiographic data.

Authors:  S Borges-Neto; L J Shaw; K L Kesler; M W Hanson; E D Peterson; E I Morris; R E Coleman
Journal:  J Nucl Cardiol       Date:  1997 May-Jun       Impact factor: 5.952

8.  Correlation between dual-axis rotational coronary angiography and intravascular ultrasound in a coronary lesion assessment.

Authors:  Zhi-Geng Jin; Zhuo-Qi Zhang; Li-Min Jing; Yu-Jie Wei; Jiao Zhang; Jian-Ping Luo; Sheng-Li Yang; Dong-Xing Ma; Ying Liu; Wei Han; Yong Yang; Hui-Liang Liu
Journal:  Int J Cardiovasc Imaging       Date:  2016-10-11       Impact factor: 2.357

9.  Assessment of the severity of coronary artery disease at postmortem examination. Are the measurements clinically valid?

Authors:  J M Mann; M J Davies
Journal:  Br Heart J       Date:  1995-11

Review 10.  Clinical correlates of the coronary arteriogram.

Authors:  R I Hamby
Journal:  Cardiovasc Intervent Radiol       Date:  1982       Impact factor: 2.740