Embolization via collateral circulation during carotid stenting with the distal balloon protection system.

N Al-Mubarak1, J J Vitek, S Iyer, G New, M B Leon, G S Roubin.   

Abstract

PURPOSE: To describe a potential route for embolization to the middle cerebral artery (MCA) during carotid stenting with the distal balloon protection system. CASE REPORT: An 82-year-old man with symptomatic severe carotid artery stenosis underwent elective carotid stenting with distal-balloon protection. Despite complete occlusion of the distal internal carotid artery, frequent emboli were detected in the ipsilateral MCA by transcranial Doppler (TCD) during the procedure. Intracranial angiography, performed during the distal-balloon protection, revealed filling of the MCA through collaterals from the ipsilateral external carotid artery. The procedure was successfully completed without complications. The patient remains asymptomatic at 6 months.
CONCLUSIONS: During carotid stenting with distal-balloon protection, asymptomatic embolization into the ipsilateral MCA may occur through collateral circulation. The clinical significance of these emboli is uncertain.

Entities:  

Mesh:

Year:  2001        PMID: 11552727     DOI: 10.1177/152660280100800404

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  2 in total

1.  Carotid artery stent placement with distal balloon protection: technical considerations.

Authors:  Jiri J Vitek; Nadim Al-Mubarak; Sriram S Iyer; Gary S Roubin
Journal:  AJNR Am J Neuroradiol       Date:  2005-04       Impact factor: 3.825

2.  Simulation Study of Distal Balloon Protection Systems during Carotid Artery Stenting.

Authors:  T Kuroiwa; N Sakai; M Sakaguchi; H Adachi; H Imamura; C Sakai; A Morizane; H Ishihara; T Yano; S Nakao; H Kikuchi
Journal:  Interv Neuroradiol       Date:  2008-05-15       Impact factor: 1.610

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.