Literature DB >> 11552409

[Toric intraocular lenses. Clinical results and rotational stability].

G Gerten1, A Michels, A Olmes.   

Abstract

BACKGROUND: Correction of an astigmatism at the time of cataract surgery can be achieved in two different ways, by alteration of the corneal curvature or by implantation of a toric intraocular lens (toric IOL). In the latter, in addition to the wound architecture and IOL calculation, the influence of rotational stability in the capsular bag is most important for the refractive result. PATIENTS AND METHODS: This retrospective study included 26 eyes from 24 patients with a corneal astigmatism of 2.5-11 D before cataract surgery of which 24 eyes showed a congenital astigmatism and 2 eyes an astigmatism after keratoplasty. After phakoemulsification a three-piece toric PMMA customised IOL (6.5/13.75 mm) was implanted into the capsular bag. Subjective and objective refraction as well as keratometry and corneal topography were performed pre- and postoperatively. The axis of the toric IOL cylinder was marked and could be measured precisely in the postoperative period. The surgically induced astigmatism (SIA) was calculated.
RESULTS: At a mean follow-up time of 12 months after the implantation of a toric IOL, all eyes showed a reduction of total astigmatism. The mean total refractive astigmatism could be reduced from 4.16 D +/- 1.58 D preoperatively to 1.64 D +/- 1.21 D postoperatively. In 6 out of the 26 eyes (23%) the toric IOL rotated more than 10 degrees in the capsular bag and in all 6 cases the IOL rotation happened in the first 3 weeks postoperation. The IOL position was surgically corrected within 3-6 weeks after initial surgery and remained stable during the follow-up period.
CONCLUSIONS: The implantation of a PMMA toric IOL is a promising procedure to correct higher levels of corneal astigmatism in cataract surgery. The initial rotational stability of the haptics in the capsular bag still has to be improved and the corneal SIA has to be reduced by smaller incisions. Therefore, three-piece foldable IOLs with a new haptic design are under development.

Entities:  

Mesh:

Year:  2001        PMID: 11552409     DOI: 10.1007/s003470170077

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  14 in total

1.  [In vitro and in vivo investigations on the treatment of presbyopia using femtosecond lasers].

Authors:  G Gerten; T Ripken; P Breitenfeld; R R Krueger; O Kermani; H Lubatschowski; U Oberheide
Journal:  Ophthalmologe       Date:  2007-01       Impact factor: 1.059

2.  [Microincision intraocular lens with plate haptic design. Evaluation of rotational stability and centering of a microincision intraocular lens with plate haptic design in 12-19 months of follow-up].

Authors:  W Wehner
Journal:  Ophthalmologe       Date:  2007-05       Impact factor: 1.059

3.  [Determination of toric intraocular lenses].

Authors:  A Langenbucher; Anja Viestenz; N Szentmáry; W Behrens-Baumann; A Viestenz
Journal:  Ophthalmologe       Date:  2008-07       Impact factor: 1.059

4.  Contact lenses and special back surface design after penetrating keratoplasty to improve contact lens fit and visual outcome.

Authors:  C Gruenauer-Kloevekorn; U Kloevekorn-Fischer; G I W Duncker
Journal:  Br J Ophthalmol       Date:  2005-12       Impact factor: 4.638

5.  [Correction of corneal astigmatism with toric lenses : Theory and clinical aspects].

Authors:  A Langenbucher; A Viestenz; N Szentmáry; A Viestenz; T Eppig; B Seitz
Journal:  Ophthalmologe       Date:  2010-02       Impact factor: 1.059

6.  Outcomes and possible risk factors associated with axis alignment and rotational stability after implantation of the Toric implantable collamer lens for high myopic astigmatism.

Authors:  Xun-Lun Sheng; Wei-Ning Rong; Qin Jia; Ya-Ni Liu; Wen-Juan Zhuang; Qing Gu; Yan Sun; Bo Pan; De-Jun Zhu
Journal:  Int J Ophthalmol       Date:  2012-08-18       Impact factor: 1.779

7.  [Rotational stability in intraocular lenses with C-loop haptics versus Z haptics in cataract surgery. A prospective randomised comparison].

Authors:  I Warlo; F Krummenauer; H B Dick
Journal:  Ophthalmologe       Date:  2005-10       Impact factor: 1.059

8.  [Toric intraocular lenses for correction of persistent corneal astigmatism after penetrating keratoplasty].

Authors:  A Viestenz; M Küchle; B Seitz; A Langenbucher
Journal:  Ophthalmologe       Date:  2005-02       Impact factor: 1.059

9.  [Predictability of residual astigmatism after implantation of posterior chamber toric lenses].

Authors:  D Mies; T Klink; W Eisenbarth; L M Meyer
Journal:  Ophthalmologe       Date:  2018-01       Impact factor: 1.059

Review 10.  [Toric IOLs after cataract surgery and refractive lens exchange].

Authors:  G U Auffarth; T M Rabsilber
Journal:  Ophthalmologe       Date:  2007-12       Impact factor: 1.059

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.