Literature DB >> 1155147

Signal characteristics of EMG with special reference to reproducibility of measurements.

J H Viitasalo, P V Komi.   

Abstract

Reliability and constancy of recordings of EMG signal characteristics were investigated from the measurements taken with miniature size surface electrodes during submaximal and maximal contraction of the rectus femoris muscle. The following EMG variables were studied: integrated EMG (IEMG) various bandwidths of the power spectral density function, mean power frequency (MPF), and rise time, amplitude and number of spikes of the averaged motor unit potential (AMUP). The results indicated that for most of the variables studied the reproducibility of measurements was better within the test session (reliability) than between the different test days (constancy). The reliability values for IEMG, MPF and AMUP amplitude were rather high (r=0.77-0.93) and it is suggested that these parameters can be recommended for use in EMG studies where recordings are repeated over a period of several days.

Mesh:

Year:  1975        PMID: 1155147     DOI: 10.1111/j.1748-1716.1975.tb05845.x

Source DB:  PubMed          Journal:  Acta Physiol Scand        ISSN: 0001-6772


  13 in total

1.  The reproducibility of test contractions for calibration of electromyographic measurements.

Authors:  K B Veiersted
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1991

2.  Reproducibility of the mean power frequency of the surface electromyogram.

Authors:  H A Daanen; M Mazure; M Holewijn; E A Van der Velde
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1990

3.  Reproducibility of kinetics of electromyogram spectrum parameters during dynamic exercise.

Authors:  D Gamet; J Duchêne; F Goubel
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1996

4.  Signal characteristics of EMG during fatigue.

Authors:  J H Viitasalo; P V Komi
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1977-09-16

5.  Activation characteristics of shoulder muscles during maximal and submaximal efforts.

Authors:  Christoph Anders; Susanne Bretschneider; Annette Bernsdorf; Wolfgang Schneider
Journal:  Eur J Appl Physiol       Date:  2004-12-14       Impact factor: 3.078

6.  Reproducibility of electromyographic patterns in stretch-shortening type contractions.

Authors:  A Gollhofer; G A Horstmann; D Schmidtbleicher; D Schönthal
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1990

7.  Effects of fatigue and recovery on electromyographic and isometric force- and relaxation-time characteristics of human skeletal muscle.

Authors:  K Häkkinen; P V Komi
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1986

Review 8.  Modelling myoelectric interference patterns during movement.

Authors:  M H Sherif; R J Gregor
Journal:  Med Biol Eng Comput       Date:  1986-01       Impact factor: 2.602

9.  Effect of isometric strength training of mechanical, electrical, and metabolic aspects of muscle function.

Authors:  P V Komi; J T Viitasalo; R Rauramaa; V Vihko
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1978-12-15

10.  Shoulder muscle load and muscle fatigue among industrial sewing-machine operators.

Authors:  B R Jensen; B Schibye; K Søgaard; E B Simonsen; G Sjøgaard
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1993
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.