Literature DB >> 11551015

Polymerization shrinkage of densely-filled resin composites.

T C Aw1, J I Nicholls.   

Abstract

A new group of restorative materials called "packable" composites has recently been introduced. These products are essentially highly-filled or densely-filled hybrid resin composites. One of the many claims made about these materials is that they undergo less polymerization shrinkage than their conventional counterparts. This in vitro investigation compared the amount of linear shrinkage that occurs within a variety of densely filled resin composites (DFC) and conventional hybrid resin composites when cured with a visible halogen light. Six DFC resins (Alert, Ariston, P60, Prodigy, Solitaire and Surefil) and two hybrids (TPH-Spectrum, Z100) were used in this study. Dimensional change was measured in a linear direction using a calibrated light microscope. Eighty samples of resin composite were tested, resulting in eight groups of 10 samples (N=10) each. The one-way ANOVA with Student-Newman-Keuls post-hoc test was used to compare the shrinkage between groups, and Pearson's Correlation was used to test the relationship between filler characteristics and shrinkage. Alert and P-60 had significantly less shrinkage than Solitaire, Ariston, Prodigy, Z-100 and TPH-S. Thus, the shrinkage values of some DFC resins were significantly less and others were no different from conventional hybrid resins. There is a moderate association between filler volume and shrinkage. Filler size and resin chemistry are other factors that may also effect shrinkage.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11551015

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  6 in total

1.  Microhardness and polymerization shrinkage of flowable resins that are light cured using a blue laser.

Authors:  Chang-Mo Jeong; Young-Joon Heo; Young-Chan Jeon; Hyung-Il Kim; Yong Hoon Kwon
Journal:  Lasers Med Sci       Date:  2011-07-24       Impact factor: 3.161

2.  Influence of DPSS laser on polymerization shrinkage and mass change of resin composites.

Authors:  Dong-Hee Shin; Dong-In Yun; Mi-Gyong Park; Ching-Chang Ko; Franklin García-Godoy; Hyung-Il Kim; Yong Hoon Kwon
Journal:  Photomed Laser Surg       Date:  2011-03-21       Impact factor: 2.796

3.  Physical properties of self-, dual-, and light-cured direct core materials.

Authors:  Stefan Rüttermann; Ian Alberts; Wolfgang H M Raab; Ralf R Janda
Journal:  Clin Oral Investig       Date:  2010-04-07       Impact factor: 3.573

4.  Effect of pre-heating composite resin on gap formation at three different temperatures.

Authors:  Nilabh Choudhary; Sharad Kamat; Tm Mangala; Mohan Thomas
Journal:  J Conserv Dent       Date:  2011-04

5.  Comparative evaluation of microleakage in class II cavities restored with Ceram X and Filtek P-90: An in vitro study.

Authors:  Poonam Bogra; Saurabh Gupta; Saru Kumar
Journal:  Contemp Clin Dent       Date:  2012-01

6.  Comparison of the Shear Bond Strength of Silorane-Based Composite Resin and Methacrylate Based Composite Resin to MTA.

Authors:  Buse Ayse Serin; Muharrem Cem Dogan; Hamdi Oguz Yoldas
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2018-03-14
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.