Literature DB >> 11549510

Autologous, cadaveric, and synthetic materials used in sling surgery: comparative biomechanical analysis.

J M Choe1, R Kothandapani, L James, D Bowling.   

Abstract

OBJECTIVES: To compare the biomechanical properties of allografts, autografts, and synthetic materials used in sling surgery using the Instron tensinometer.
METHODS: The sling grafts we studied consisted of autologous tissues (dermis, rectus fascia, and vaginal mucosa), cadaver tissues (decellularized dermis and freeze-dried, gamma-irradiated fascia lata), and synthetics (Gore-Tex and polypropylene mesh). The sling grafts were constructed into two types of slings: full strip sling (FSS) versus patch suture sling (PSS). The slings were loaded onto the Instron tensinometer and uniaxially loaded in tension until failure. From the load deformation curve, the mechanical properties of the sling grafts were compared.
RESULTS: A total of 140 sling grafts were analyzed. In rank order for the FSSs, cadaver allografts had the strongest tensile strength followed by the synthetics and autologous tissues (P <0.05). The tensile strength of the FSSs was greater than for the PSSs for all groups (P </=0.001). In rank order for the PSSs, the synthetics and dermal tissues (autograft and allograft) had the highest tensile strength followed by cadaver fascia lata, rectus fascia, and vaginal mucosa (P <0.05).
CONCLUSIONS: The tensile strength of the FSS was greater than that of the PSS for the autograft, allograft, and synthetic tissues. The autograft and allograft tissues were significantly weaker as a PSS. The synthetics were more durable as a PSS compared with the organic tissues. When a PSS is constructed from autograft and allograft tissues, the risk of suture pull-through and recurrent stress incontinence must be considered.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11549510     DOI: 10.1016/s0090-4295(01)01205-5

Source DB:  PubMed          Journal:  Urology        ISSN: 0090-4295            Impact factor:   2.649


  17 in total

1.  Does size matter? Technical considerations of a regenerative tissue matrix for use in reconstructive surgery.

Authors:  Randall O Craft; Alanna M Rebecca; Colleen Flahive; William J Casey; Amylou Dueck; Kristi L Harold
Journal:  Can J Plast Surg       Date:  2011

2.  A complex fistula caused by an eroding pelvic mesh sling.

Authors:  Ugo Ihedioha; E Leung; L Chung; G Burgess; D Hendry; P J O'dwyer
Journal:  Hernia       Date:  2006-09-23       Impact factor: 4.739

3.  Solvent-dehydrated dermal allograft (AXIS™) augmented cystocele repair: longitudinal results.

Authors:  Saad Juma; Omer A Raheem
Journal:  Int Urogynecol J       Date:  2016-12-30       Impact factor: 2.894

4.  Re: Influence of TVT properties on outcomes of midurethral sling procedures: high-stiffness versus low-stiffness tape.

Authors:  Tony Bazi
Journal:  Int Urogynecol J       Date:  2016-09-19       Impact factor: 2.894

5.  Assessing outcome after a modified vaginal wall sling for stress incontinence with intrinsic sphincter deficiency.

Authors:  Elisabetta Costantini; Luigi Mearini; Ettore Mearini; Cinzia Pajoncini; Federico Guercini; Vittorio Bini; Massimo Porena
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2004-10-22

6.  Reconstruction of parasacral hernia with acellular human dermis graft.

Authors:  J B Brizendine; J F LeFaivre; M J Yost; S A Fann
Journal:  Hernia       Date:  2006-05-17       Impact factor: 4.739

7.  Results of AlloDerm use in abdominal hernia repair.

Authors:  S Misra; P K Raj; S M Tarr; R C Treat
Journal:  Hernia       Date:  2008-01-22       Impact factor: 4.739

8.  A randomized comparison between monofilament and multifilament tapes for stress incontinence surgery.

Authors:  Tomasz Rechberger; Katarzyna Rzeźniczuk; Paweł Skorupski; Aneta Adamiak; Jacek Tomaszewski; Włodzimierz Baranowski; Jerzy A Jakowicki
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2003-11-25

9.  Blood vessel matrix: a new alternative for abdominal wall reconstruction.

Authors:  C F Bellows; W Jian; M K McHale; D Cardenas; J L West; S P Lerner; G E Amiel
Journal:  Hernia       Date:  2008-01-31       Impact factor: 4.739

10.  Ventral hernia repair using allogenic acellular dermal matrix in a swine model.

Authors:  R P Silverman; E N Li; L H Holton; K T Sawan; N H Goldberg
Journal:  Hernia       Date:  2004-12       Impact factor: 4.739

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.