Monte Carlo dosimetry of the selectSeed 125I interstitial brachytherapy seed.

P Karaiskos1, P Papagiannis, L Sakelliou, G Anagnostopoulos, D Baltas.   

Abstract

This work provides full dosimetric data for the new selectSeed 125I prostate seed source to be distributed by Nucletron B.V. The AAPM TG-43 dosimetric formalism and the new 1999 NIST air kerma strength calibration standard have been followed. Air kerma strength, dose rate constant, radial dose functions, anisotropy functions, and anisotropy factors were calculated using Monte Carlo simulation. Corresponding calculations were also performed for the commercially available 6711 seed source, which is of similar design, for reasons of comparison. The calculated dose rate constant of the selectSeed was 0.954+/-0.005 cGy h(-1) U(-1) compared to 0.953+/-0.005 cGy h(-1) U(-1) for the 6711 source design. The latter value for the 6711 source suggests that the correction factor proposed by NIST for conversion of dose rate constants to the new 1999 NIST calibration standard may be overestimated by 2-3%. Radial dose functions of the two sources were found in good agreement for radial distances up to 4 cm, the selectSeed being less penetrating at greater radial distances (approximately 4% at 10 cm). The selectSeed source presents similar anisotropy characteristics with the 6711 source design. For both source designs, a distance and polar angle dependent discontinuity of anisotropy function values was observed owing to the dose contribution of radioactivity distributed on the ends of the cylindrical source cores. Variation of dosimetric parameters with possible variation in radioactive silver halide coating thickness of the silver source core of the new source was also investigated.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11548946     DOI: 10.1118/1.1384460

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: report of AAPM Task Group No. 138 and GEC-ESTRO.

Authors:  Larry A DeWerd; Geoffrey S Ibbott; Ali S Meigooni; Michael G Mitch; Mark J Rivard; Kurt E Stump; Bruce R Thomadsen; Jack L M Venselaar
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

2.  Reconstruction of brachytherapy seed positions and orientations from cone-beam CT x-ray projections via a novel iterative forward projection matching method.

Authors:  Damodar Pokhrel; Martin J Murphy; Dorin A Todor; Elisabeth Weiss; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

3.  An EGSnrc investigation of the air-kerma strength, dose rate constant, and radial dose function of 125I brachytherapy sources.

Authors:  Sridhar Sahoo; T Palani Selvam
Journal:  Radiol Phys Technol       Date:  2009-07-11

4.  New (125)I brachytherapy source IsoSeed I25.S17plus: Monte Carlo dosimetry simulation and comparison to sources of similar design.

Authors:  Evaggelos Pantelis; Panagiotis Papagiannis; Giorgos Anagnostopoulos; Dimos Baltas
Journal:  J Contemp Brachytherapy       Date:  2013-12-21

5.  Monte Carlo investigation of energy response of various detector materials in ¹²⁵I and ¹⁶⁹Yb brachytherapy dosimetry.

Authors:  T Palani Selvam; Biju Keshavkumar
Journal:  J Appl Clin Med Phys       Date:  2010-07-28       Impact factor: 2.102

6.  A technical evaluation of the Nucletron FIRST system: conformance of a remote afterloading brachytherapy seed implantation system to manufacturer specifications and AAPM Task Group report recommendations.

Authors:  Mark J Rivard; Dee-Ann Radford Evans; Ian Kay
Journal:  J Appl Clin Med Phys       Date:  2005-01-12       Impact factor: 2.102

Review 7.  A brief look at model-based dose calculation principles, practicalities, and promise.

Authors:  Ron S Sloboda; Hali Morrison; Brie Cawston-Grant; Geetha V Menon
Journal:  J Contemp Brachytherapy       Date:  2017-02-08
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.