Literature DB >> 11547378

Total hip arthroplasty with a modified cementing technique using hydroxyapatite granules.

H Oonishi1, Y Kadoya, H Iwaki, N Kin.   

Abstract

Results of total hip arthroplasties with a modified cementing technique using hydroxyapatite were evaluated. Femoral and acetabular components were inserted with cement after hydroxyapatite granules (phi = 100-300 microm). The study group comprised 268 hips in 232 patients. The diagnosis was osteoarthritis in 197 patients. After a mean follow-up of 10.3 years, 5 patients died and 30 patients were lost to follow-up, leaving 218 hips (197 patients; mean age, 58.2 years) for evaluation. Three hips were revised because aseptic (1) and septic (2) loosening of acetabular components. Six other sockets were defined as radiologically loose, and no femoral component was loose. Osteolysis was identified in 2 femora and 0 acetabula. The overall loosening rate was 3.2% for acetabular components and 0% for femoral components. These results show that the loosening rate of cemented total hip arthroplasty components, especially the acetabulum, is reduced markedly with this modified cementing technique.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11547378     DOI: 10.1054/arth.2001.23724

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  Prospective, comparative study of cemented, smooth-surfaced titanium stems and polish-surfaced, stainless steel stems at a minimum follow-up of 10 years.

Authors:  Hiroshi Fujita; Hiroaki Hara; Hideto Harada; Masanao Kataoka; Tomohiro Tominaga; Ryuuichi Nishimura
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-11-18

2.  THA with hydroxyapatite granules at cement-bone interface: 15- to 20-year results.

Authors:  Hironobu Oonishi; Hirotsugu Ohashi; Hiroyuki Oonishi; Sok Chol Kim
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

3.  A modified cementing technique using BoneSource to augment fixation of the acetabulum in a sheep model.

Authors:  A John Timperley; Iulian Nusem; Kathy Wilson; Sarah L Whitehouse; Pieter Buma; Ross W Crawford
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

Review 4.  Total Hip Arthroplasty around the Inception of the Interface Bioactive Bone Cement Technique.

Authors:  Hiroyuki Oonishi; Hirotsugu Ohashi; Ikuo Kawahara
Journal:  Clin Orthop Surg       Date:  2016-08-10

5.  A case report of idiopathic iliopsoas hematoma which occurred soon after transfer to the wheelchair after total hip arthroplasty.

Authors:  Tomoo Okumura; Hiroshi Fujita; Hideto Harada; Ryuuichi Nishimura; Tomohiro Tominaga
Journal:  Nagoya J Med Sci       Date:  2017-02       Impact factor: 1.131

6.  Influence of the knot position on the union of the greater trochanter after bipolar hip arthroplasty via the modified Dall approach: a prospective non-randomized study.

Authors:  Masanao Kataoka; Hiroshi Fujita; Hiroaki Hara; Hideto Harada; Yuki Okutani; Yoshiki Murotani
Journal:  BMC Musculoskelet Disord       Date:  2021-02-10       Impact factor: 2.362

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.