Literature DB >> 11547369

Correction of limb-length inequality during total hip arthroplasty.

C S Ranawat1, R R Rao, J A Rodriguez, H S Bhende.   

Abstract

Although several methods of intraoperative limb-length measurements have been described, their success in predicting the limb-length correction is not well documented. A new technique of measuring intraoperative limb lengthening using a vertical Steinmann pin at the infracotyloid groove of the acetabulum was studied in 100 consecutive primary total hip arthroplasties. Correlation of the predicted intraoperative correction was done with the postoperative radiographic measurements. Preoperative limb-length inequality ranged from -24 mm (short) to +2 mm (long) (mean, -4.2 mm). Intraoperative measurement of lengthening ranged from 0 to 15 mm (mean, 5.9 mm). Radiographic measurements of postoperative radiographs showed lengthening ranging from 0 to 17 mm (mean, 7.4 mm). There was significant correlation between the 2 values (r =.84). Postoperative limb-length inequality ranged from -7 mm to +8 mm (mean, 1.9 mm). None of the patients had to use shoe lifts for equalization of limb lengths.

Entities:  

Mesh:

Year:  2001        PMID: 11547369     DOI: 10.1054/arth.2001.24442

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  50 in total

1.  [Is shorter really better? : Philosophy of short stem prosthesis designs].

Authors:  J Jerosch
Journal:  Orthopade       Date:  2011-12       Impact factor: 1.087

2.  Preoperative radiographic assessment of limb-length discrepancy in total hip arthroplasty.

Authors:  Geert Meermans; Ahmad Malik; Johan Witt; Fares Haddad
Journal:  Clin Orthop Relat Res       Date:  2010-09-29       Impact factor: 4.176

3.  Leg length discrepancy in total hip arthroplasty: comparison of two methods of measurement.

Authors:  Arkan S Sayed-Noor; Anders Hugo; Göran O Sjödén; Per Wretenberg
Journal:  Int Orthop       Date:  2008-08-02       Impact factor: 3.075

4.  A multimodal approach in total hip arthroplasty preoperative templating.

Authors:  Massimiliano Marcucci; Pier Francesco Indelli; Leonardo Latella; Paolo Poli; Devin King
Journal:  Skeletal Radiol       Date:  2013-07-05       Impact factor: 2.199

5.  Leg length discrepancy after total hip arthroplasty: a review of literature.

Authors:  Aravind S Desai; Asterios Dramis; Tim N Board
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

6.  Dislocation after total hip arthroplasty.

Authors:  A Zahar; A Rastogi; D Kendoff
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

7.  Leg length and offset measures with a pinless femoral reference array during THA.

Authors:  Tobias Renkawitz; Tibor Schuster; Joachim Grifka; Thomas Kalteis; Ernst Sendtner
Journal:  Clin Orthop Relat Res       Date:  2009-09-19       Impact factor: 4.176

8.  Improvement of activities of daily living after total hip arthroplasty using a computed tomography-based navigation system.

Authors:  Yuki Maeda; Nobuo Nakamura; Nobuhiko Sugano
Journal:  J Artif Organs       Date:  2017-02-27       Impact factor: 1.731

9.  Fluoroscopy and imageless navigation enable an equivalent reconstruction of leg length and global and femoral offset in THA.

Authors:  Markus Weber; Michael Woerner; Robert Springorum; Ernst Sendtner; Alexander Hapfelmeier; Joachim Grifka; Tobias Renkawitz
Journal:  Clin Orthop Relat Res       Date:  2014-06-26       Impact factor: 4.176

10.  Does fluoroscopy with anterior hip arthroplasty decrease acetabular cup variability compared with a nonguided posterior approach?

Authors:  Parthiv A Rathod; Sean Bhalla; Ajit J Deshmukh; Jose A Rodriguez
Journal:  Clin Orthop Relat Res       Date:  2014-02-19       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.