Literature DB >> 11547366

Matched-pair analysis of all-polyethylene versus metal-backed tibial components.

P Udomkiat1, L D Dorr, W Long.   

Abstract

Forty-eight matched pairs of osteoarthritic knees from patients who underwent primary total knee arthroplasty with a round-on-round, Apollo Knee System were studied to evaluate the outcome between all-polyethylene and metal-backed tibial components. Patients were matched for patient factors, preoperative deformities, cruciate salvage or sacrifice, and surgical technique. At the last follow-up (average, 38.4 months), there was no statistically significant difference in terms of knee scores, patient self-assessment, and radiographic outcomes. No component required revision, and no revisions were pending. Maintenance of these results over time would project into better long-term success for all-polyethylene tibial components because of the amount of wear and osteolysis with current modular metal-backed tibial components. We advocate the use of a more cost-effective all-polyethylene tibial component in elderly patients (>70 years old) who are not likely to need the versatility of exchange of a modular polyethylene insert because of wear.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11547366     DOI: 10.1054/arth.2001.25500

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  7 in total

Review 1.  Tibial component designs in primary total knee arthroplasty: should we reconsider all-polyethylene component?

Authors:  Tao Cheng; Xiaoyun Pan; Tao Liu; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-05       Impact factor: 4.342

2.  All-polyethylene tibial components in obese patients are associated with low failure at midterm followup.

Authors:  David F Dalury; Kimberly K Tucker; Todd C Kelley
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

Review 3.  All-polyethylene tibial components are equal to metal-backed components: systematic review and meta-regression.

Authors:  Klaas Auke Nouta; Wiebe C Verra; Bart G Pijls; Jan W Schoones; Rob G H H Nelissen
Journal:  Clin Orthop Relat Res       Date:  2012-09-13       Impact factor: 4.176

Review 4.  All-polyethylene versus metal-backed tibial component in total knee arthroplasty.

Authors:  Umile Giuseppe Longo; Mauro Ciuffreda; Valerio D'Andrea; Nicholas Mannering; Joel Locher; Vincenzo Denaro
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-05-21       Impact factor: 4.342

5.  Metal-backed versus all-polyethylene tibial components in primary total knee arthroplasty.

Authors:  Tao Cheng; Guoyou Zhang; Xianlong Zhang
Journal:  Acta Orthop       Date:  2011-09-06       Impact factor: 3.717

Review 6.  Cemented all-poly tibia in resource constrained country, affordable and cost-effective care. Is it applicable at this era? Review article.

Authors:  Vickash Kumar; Obada Hasan; Masood Umer; Naveed Baloch
Journal:  Ann Med Surg (Lond)       Date:  2019-09-27

7.  A FUNCTIONAL AND ROENTGENOGRAPHIC PRELIMINARY COMPARATIVE STUDY USING METAL-BACKED AND ALL-POLYETHYLENE TIBIAL COMPONENTS IN TOTAL KNEE ARTHROPLASTY.

Authors:  Marco Antônio Percope de Andrade; Juliano Rodrigues Dos Santos; Luiz Gustavo Alves Gonzaga; Guilherme Moreira Abreu E Silva
Journal:  Rev Bras Ortop       Date:  2015-11-17
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.