Literature DB >> 11547280

Real-time 3-dimensional echocardiography imaging for right ventricular endomyocardial biopsy: a comparison with fluoroscopy.

C J McCreery1, M McCulloch, M Ahmad, C R deFilippi.   

Abstract

Real-time 3-dimensional (RT3D) echocardiography has the potential to precisely identify the position of an object in 3-dimensional space. Therefore, we hypothesized that RT3D echocardiography could rapidly facilitate accurate placement of a bioptome within the right ventricle and may offer advantages over a fluoroscopically guided approach. During 63 routine right ventricular biopsy procedures (total of 315 biopsy attempts) in 33 cardiac allograft recipients, the bioptome was initially guided against the intraventricular septum with the use of biplane fluoroscopy. Bioptome position was then evaluated by RT3D echocardiography by using the Volumetrics Model 1 with the transducer placed at the apex. Multiple long-axis and short-axis planes were simultaneously visualized and customized to identify the tip of the bioptome. Bioptome placement was prospectively classified as septal, free wall/septal junction, or free wall. Of the 36 patients studied, 33 (91%) had adequate RT3D images. Of 315 bioptome placements visualized by RT3D echocardiography after fluoroscopic placement, bioptome position against the septum was confirmed in 113 (36%), against the septal/free wall (anterior or posterior) junction in 140 (44%), against the free wall in 60 (19%), and in the coronary sinus in 2 (1%). RT3D echocardiography is readily feasible for use in the majority of transplant patients undergoing right ventricular endomyocardial biopsy. Visualization of the bioptome in multiple simultaneous planes allows accurate localization of the biopsy site. The potential for improved localization of the bioptome tip in the right ventricle may have important clinical implications for augmenting the efficacy of this procedure.

Entities:  

Mesh:

Year:  2001        PMID: 11547280     DOI: 10.1067/mje.2001.113651

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  5 in total

1.  Evaluation of right ventricular volume and systolic function by realtime three-dimensional echocardiography.

Authors:  Jing Wang; Xinfang Wang; Mingxing Xie; Ya Yang; Qing L V; Ying Yang; Liangyu Wang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2005

2.  Vibrating interventional device detection using real-time 3-D color Doppler.

Authors:  Matthew P Fronheiser; Salim F Idriss; Patrick D Wolf; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008       Impact factor: 2.725

3.  Is Endomyocardial Biopsy a Safe and Useful Procedure in Children with Suspected Cardiomyopathy?

Authors:  Kimberly I Mills; Julie A Vincent; Warren A Zuckerman; Timothy M Hoffman; Charles E Canter; Audrey C Marshall; Elizabeth D Blume; Lisa Bergersen; Kevin P Daly
Journal:  Pediatr Cardiol       Date:  2016-06-06       Impact factor: 1.655

4.  Real-time 3-D ultrasound guidance of interventional devices.

Authors:  Edward D Light; John F Angle; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-09       Impact factor: 2.725

Review 5.  Endomyocardial Biopsy in Pediatric Myocarditis and Dilated Cardiomyopathy: A Tool in Search for a Role.

Authors:  Mara Pilati; Micol Rebonato; Roberto Formigari; Gianfranco Butera
Journal:  J Cardiovasc Dev Dis       Date:  2022-01-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.