OBJECTIVE: To compare the effect on respiratory function of different continuous positive airway pressure systems and periodic hyperinflations in patients with respiratory failure. DESIGN: Prospective SETTING: Hospital intensive care unit. PATIENTS: Sixteen intubated patients (eight men and eight women, age 54 +/- 18 yrs, PaO2/FiO2 277 +/- 58 torr, positive end-expiratory pressure 6.2 +/- 2.0 cm H2O). INTERVENTIONS: We evaluated continuous flow positive airway pressure systems with high or low flow plus a reservoir bag equipped with spring-loaded mechanical or underwater seal positive end-expiratory pressure valve and a continuous positive airway pressure by a Servo 300 C ventilator with or without periodic hyperinflations (three assisted breaths per minute with constant inspiratory pressure of 30 cm H2O over positive end-expiratory pressure). MEASUREMENTS AND MAIN RESULTS: We measured the respiratory pattern, work of breathing, dyspnea sensation, end-expiratory lung volume, and gas exchange. We found the following: a) Work of breathing and gas exchange were comparable between continuous flow systems; b) the ventilator continuous positive airway pressure was not different compared with continuous flow systems; and c) continuous positive airway pressure with periodic hyperinflations reduced work of breathing (10.7 +/- 9.5 vs. 6.3 +/- 5.7 J/min, p <.05) and dyspnea sensation (1.6 +/- 1.2 vs. 1.1 +/- 0.8 cm, p <.05) increased end-expiratory lung volume (1.6 +/- 0.8 vs. 2.0 +/- 0.9 L, p <.05) and PaO2 (100 +/- 21 vs. 120 +/- 25 torr, p <.05) compared with ventilator continuous positive airway pressure. CONCLUSIONS: The continuous flow positive airway pressure systems tested are equally efficient; a ventilator can provide satisfactory continuous positive airway pressure; and the use of periodic hyperinflations during continuous positive airway pressure can improve respiratory function and reduce the work of breathing.
OBJECTIVE: To compare the effect on respiratory function of different continuous positive airway pressure systems and periodic hyperinflations in patients with respiratory failure. DESIGN: Prospective SETTING: Hospital intensive care unit. PATIENTS: Sixteen intubated patients (eight men and eight women, age 54 +/- 18 yrs, PaO2/FiO2 277 +/- 58 torr, positive end-expiratory pressure 6.2 +/- 2.0 cm H2O). INTERVENTIONS: We evaluated continuous flow positive airway pressure systems with high or low flow plus a reservoir bag equipped with spring-loaded mechanical or underwater seal positive end-expiratory pressure valve and a continuous positive airway pressure by a Servo 300 C ventilator with or without periodic hyperinflations (three assisted breaths per minute with constant inspiratory pressure of 30 cm H2O over positive end-expiratory pressure). MEASUREMENTS AND MAIN RESULTS: We measured the respiratory pattern, work of breathing, dyspnea sensation, end-expiratory lung volume, and gas exchange. We found the following: a) Work of breathing and gas exchange were comparable between continuous flow systems; b) the ventilator continuous positive airway pressure was not different compared with continuous flow systems; and c) continuous positive airway pressure with periodic hyperinflations reduced work of breathing (10.7 +/- 9.5 vs. 6.3 +/- 5.7 J/min, p <.05) and dyspnea sensation (1.6 +/- 1.2 vs. 1.1 +/- 0.8 cm, p <.05) increased end-expiratory lung volume (1.6 +/- 0.8 vs. 2.0 +/- 0.9 L, p <.05) and PaO2 (100 +/- 21 vs. 120 +/- 25 torr, p <.05) compared with ventilator continuous positive airway pressure. CONCLUSIONS: The continuous flow positive airway pressure systems tested are equally efficient; a ventilator can provide satisfactory continuous positive airway pressure; and the use of periodic hyperinflations during continuous positive airway pressure can improve respiratory function and reduce the work of breathing.
Authors: Felipe Saddy; Gisele P Oliveira; Cristiane S N B Garcia; Liliane M Nardelli; Andreia F Rzezinski; Debora S Ornellas; Marcelo M Morales; Vera L Capelozzi; Paolo Pelosi; Patricia R M Rocco Journal: Intensive Care Med Date: 2010-03-24 Impact factor: 17.440
Authors: Carolina Fu; Pedro Caruso; Jeanette Janaina Jaber Lucatto; Guilherme Pinto de Paula Schettino; Rogério de Souza; Carlos Roberto Ribeiro Carvalho Journal: Intensive Care Med Date: 2005-10-13 Impact factor: 17.440
Authors: Giuseppe Foti; Fabio Sangalli; Lorenzo Berra; Stefano Sironi; Marco Cazzaniga; Gian Piera Rossi; Giacomo Bellani; Antonio Pesenti Journal: Intensive Care Med Date: 2008-11-22 Impact factor: 17.440
Authors: Stefano Isgrò; Alberto Zanella; Chiara Sala; Giacomo Grasselli; Giuseppe Foti; Antonio Pesenti; Nicolò Patroniti Journal: Intensive Care Med Date: 2010-06-03 Impact factor: 17.440