Literature DB >> 11536020

Use of capnography in the delivery room for assessment of endotracheal tube placement.

J E Repetto1, P K Donohue PA-C, S F Baker, L Kelly, L M Nogee.   

Abstract

OBJECTIVE: Determine whether end-tidal CO(2) (ETCO(2)) monitoring allows for more rapid discrimination of tracheal versus esophageal intubation than standard clinical assessment during neonatal resuscitation in the delivery room. STUDY
DESIGN: Endotracheal tube (ETT) placement was assessed using either a hand-held monitor that displayed graphic and quantitative ETCO(2) by an investigator not involved in the resuscitation, or using clinical parameters by the resuscitation team unaware of the ETCO(2) data. The time differences between ETCO(2) and clinical determinations of ETT placement were compared.
RESULTS: Capnography correctly identified all 16 tracheal and 11 esophageal intubations performed on 16 study infants. The median times (and range) in seconds required for capnographic and clinical determination of tracheal intubation were 9 (4 to 26) vs. 35 (18 to 70), p<.001, and for esophageal intubation were 9 (4 to 17) vs. 30 (25 to 111), p=.001.
CONCLUSION: Capnography allowed more rapid determination of both tracheal and unintended esophageal intubation than clinical assessment.

Entities:  

Mesh:

Year:  2001        PMID: 11536020     DOI: 10.1038/sj.jp.7210534

Source DB:  PubMed          Journal:  J Perinatol        ISSN: 0743-8346            Impact factor:   2.521


  12 in total

Review 1.  Are carbon dioxide detectors useful in neonates?

Authors:  E J Molloy; K Deakins
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2006-07       Impact factor: 5.747

2.  Singapore Neonatal Resuscitation Guidelines 2016.

Authors:  Cheo Lian Yeo; Agnihotri Biswas; Teong Tai Kenny Ee; Amutha Chinnadurai; Vijayendra Ranjan Baral; Alvin Shang Ming Chang; Imelda Lustestica Ereno; Kah Ying Selina Ho; Woei Bing Poon; Varsha Atul Shah; Bin Huey Quek
Journal:  Singapore Med J       Date:  2017-07       Impact factor: 1.858

3.  T-piece gas flow palpation as a clinical indicator of endotracheal intubation in neonates.

Authors:  Peter M Moran; Colin Patrick Hawkes; Eugene Michael Dempsey; C Anthony Ryan
Journal:  Eur J Pediatr       Date:  2012-12-28       Impact factor: 3.183

4.  Singapore Neonatal Resuscitation Guidelines 2021.

Authors:  Agnihotri Biswas; Selina Kah Ying Ho; Wai Yan Yip; Khadijah Binti Abdul Kader; Juin Yee Kong; Kenny Teong Tai Ee; Vijayendra Ranjan Baral; Amutha Chinnadurai; Bin Huey Quek; Cheo Lian Yeo
Journal:  Singapore Med J       Date:  2021-08       Impact factor: 1.858

5.  Neonatal resuscitation: Current issues.

Authors:  Indu A Chadha
Journal:  Indian J Anaesth       Date:  2010-09

6.  Assessment of endotracheal tube placement in newborn infants: a randomized controlled trial.

Authors:  S van Os; P-Y Cheung; K Kushniruk; M O'Reilly; K Aziz; G M Schmölzer
Journal:  J Perinatol       Date:  2016-01-14       Impact factor: 2.521

Review 7.  Question 2. Should carbon dioxide detectors be used to check correct placement of endotracheal tubes in preterm and term neonates?

Authors:  Harsha Gowda
Journal:  Arch Dis Child       Date:  2011-12       Impact factor: 3.791

Review 8.  WITHDRAWN: Techniques to ascertain correct endotracheal tube placement in neonates.

Authors:  Georg M Schmölzer; Charles Christoph C Roehr
Journal:  Cochrane Database Syst Rev       Date:  2018-07-05

Review 9.  [Newborn resuscitation and support of transition of infants at birth].

Authors:  John Madar; Charles C Roehr; Sean Ainsworth; Hege Ersda; Colin Morley; Mario Rüdiger; Christiane Skåre; Tomasz Szczapa; Arjan Te Pas; Daniele Trevisanuto; Berndt Urlesberger; Dominic Wilkinson; Jonathan P Wyllie
Journal:  Notf Rett Med       Date:  2021-06-02       Impact factor: 0.892

Review 10.  Enhanced Monitoring of the Preterm Infant during Stabilization in the Delivery Room.

Authors:  Daragh Finn; Geraldine B Boylan; C Anthony Ryan; Eugene M Dempsey
Journal:  Front Pediatr       Date:  2016-03-31       Impact factor: 3.418

View more