Exposure to indoor allergens is associated with asthma, but there is no standardized sampling method for measuring allergens. We compared the association of measured allergen exposure and serum-specific IgE levels and the precision of three sampling methods (Cyclone, Mighty Mite, and Readivac II) to identify a standardized sampling method for indoor allergens. A random sample of 72 children, 5 to 17 years old, with doctor-diagnosed asthma who lived in the same residence >or=2 years were enrolled. Composite, side by side floor samples were obtained with all three methods. Dust allergen concentrations and serum-specific IgE levels were measured for Der f I, Fel d I, and Bla g I. Mean allergen concentration did not differ significantly by sampling method. Cat allergen was significantly correlated with serum-specific IgE for Cyclone (P=0.003) and Mighty Mite (P=0.008), but only marginally for Readivac II (P=0.07). Dust mite allergen was significantly correlated with serum-specific IgE for Readivac II (P=0.02) and Cyclone (P=0.038), but not for Mighty Mite (P=0.12). Cockroach allergen was not correlated with serum-specific IgE for any sampling method. In multiple linear regression, cat allergen was associated with serum-specific IgE for Cyclone (P=0.007) and Mighty Mite (P=0.02), but not for Readivac II (P=0.06). In contrast, dust mite allergen was marginally associated with serum-specific IgE for Readivac II (P=0.07), but not for Mighty Mite (P=0.64) or Cyclone (P=0.27). The Cyclone and Mighty Mite were more precise than Readivac II for cat allergen, but there was no difference for dust mite allergen (P>0.05). No single method is superior for measurement of indoor allergens. In general, cat allergen collected with the Cyclone was a better predictor of serum-specific IgE levels to Fel d I, whereas dust mite allergen collected with the Readivac II was a better predictor of serum-specific IgE levels to Der f I. Copyright 2001 Academic Press.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11534963     DOI: 10.1006/enrs.2001.4284

Source DB:  PubMed          Journal:  Environ Res        ISSN: 0013-9351            Impact factor:   6.498


  4 in total

1.  A side-by-side comparison of three allergen sampling methods in settled house dust.

Authors:  Megan Sandel; Johnna S Murphy; Sherry L Dixon; John L Adgate; Ginger L Chew; Samuel Dorevitch; David E Jacobs
Journal:  J Expo Sci Environ Epidemiol       Date:  2014-05-07       Impact factor: 5.563

2.  The effect of home characteristics on dust antigen concentrations and loads in homes.

Authors:  Seung-Hyun Cho; Tiina Reponen; David I Bernstein; Rolanda Olds; Linda Levin; Xiaolei Liu; Kimberly Wilson; Grace Lemasters
Journal:  Sci Total Environ       Date:  2006-10-16       Impact factor: 7.963

3.  Quantitative measurement of airborne cockroach allergen in New York City apartments.

Authors:  W A Esposito; G L Chew; J C Correa; S N Chillrud; R L Miller; P L Kinney
Journal:  Indoor Air       Date:  2011-07-12       Impact factor: 5.770

4.  A comparison of subject room dust with home vacuum dust for evaluation of dust-borne aeroallergens.

Authors:  Charles Barnes; Jay M Portnoy; Christina E Ciaccio; Freddy Pacheco
Journal:  Ann Allergy Asthma Immunol       Date:  2013-03-07       Impact factor: 6.347

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.