D J Pavlin1, J Y Hong, P R Freund, M E Koerschgen, J O Bower, T A Bowdle.
Abstract
We performed this study to determine whether instituting monitoring of bispectral index (BIS) throughout an entire operating room would affect end-tidal gas concentration (as a surrogate for anesthetic use) or speed of recovery after outpatient surgery. Primary caregivers (n = 69) were randomly assigned to a BIS or non-BIS Control group with cross-over at 1-mo intervals for 7 mo. Data were obtained in all outpatients except for those having head-and-neck surgery. Mean end-tidal gas concentration and total recovery duration were compared by unpaired t-test. Overall, 469 patients (80%) received propofol for induction and sevoflurane for maintenance. This homogeneous group was selected for statistical analysis. Mean end-tidal sevoflurane concentration was 13% less in the BIS group (BIS, 1.23%; Control, 1.41%; P < 0.0001); differences were most evident when anesthesia was administered by first-year trainees. Mean BIS values were 47 in the BIS-Monitored group. Total recovery was 19 min less with BIS monitoring in men (BIS group, 147 min; Controls, 166 min; P = 0.035), but not different in women. We conclude that routine application of BIS monitoring is associated with a modest reduction in end-tidal sevoflurane concentration. In men, this may correlate with a similar reduction (11%) in recovery duration.Entities:
Mesh:
Substances:
Year: 2001 PMID: 11524328 DOI: 10.1097/00000539-200109000-00017