Literature DB >> 11517041

Reliability of soft-copy versus hard-copy interpretation of emergency department radiographs: a prototype study.

H L Kundel1, M Polansky, M K Dalinka, R H Choplin, W B Gefter, J B Kneelend, W T Miller, W T Miller.   

Abstract

OBJECTIVE: The purpose of this study was to compare the diagnostic reliability of hard-copy and soft-copy interpretation of radiographs obtained in the emergency department using a methodology for evaluating imaging systems when independent proof of the diagnosis is not available.
MATERIALS AND METHODS: We collected radiographs from a stratified sample of 100 patients seen in the emergency department. The images were obtained using computed radiography, and the digital images were printed on film and stored for display on a workstation. A group of seven experienced radiologists reported the cases using both film and the workstation display. The results were analyzed using mixture distribution analysis (MDA).
RESULTS: The reliability expressed as the percentage of agreement of a typical observer relative to the majority was computed from the MDA. The result was 90% for both hard copy and soft copy with bootstrap confidence intervals of 86-94%.
CONCLUSION: We conclude that, in the emergency department, soft-copy interpretation is as reliable as hard-copy interpretation. The strength of this conclusion depends on the validity of the MDA approach as well as the extent to which the observer sample and case sample are representative of the emergency department.

Entities:  

Mesh:

Year:  2001        PMID: 11517041     DOI: 10.2214/ajr.177.3.1770525

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  3 in total

1.  Comparison of liquid crystal versus cathode ray tube display for the detection of simulated chest lesions.

Authors:  Elisabeth Oschatz; Mathias Prokop; Martina Scharitzer; Michael Weber; Csilla Balassy; Cornelia Schaefer-Prokop
Journal:  Eur Radiol       Date:  2004-09-08       Impact factor: 5.315

2.  Can paper replace laser film to communicate the results of wrist radiographs in trauma cases? A reproducibility study of the reading of wrist trauma case radiographs on a PACS workstation, laser film, and paper.

Authors:  Pedro Teixeira; Jean-Philippe Zabel; Cédric Baumann; Stéphane Albizzati; Henry Coudane; Daniel Winninger; Alain Blum
Journal:  J Digit Imaging       Date:  2013-12       Impact factor: 4.056

3.  Reliability analysis for manual measurement of coronal plane deformity in adolescent scoliosis. Are 30 x 90 cm plain films better than digitized small films?

Authors:  Antonio De Carvalho; Raphaël Vialle; Laurent Thomsen; Julien Amzallag; Guillaume Cluzel; Hubert Ducou le Pointe; Pierre Mary
Journal:  Eur Spine J       Date:  2007-07-10       Impact factor: 3.134