Literature DB >> 11515663

Skin dose measurement by using ultra-thin TLDs.

J P Lin1, T C Chu, S Y Lin, M T Liu.   

Abstract

The treatment schedule for radiation therapy is often interrupted because of complicated skin reactions. Quantitative information relating beam parameters and skin reactions will be helpful. Measurements were performed for 6-15 MV photons and 6-21 MeV electrons with ultra thin TLD films (GR-200F, surface area 0.5 x 0.5cm2, nominal thickness 5 mg cm(-2)). The skin doses for various field sizes, ranging from 10 x 10 to 40 x 40 cm2, and various incident angles of beam from 0 degrees to 80 degrees were measured. The ratios of skin dose to maximum dose in phantom for 10 x 10 cm2 are 16.10+/-0.68%, 14.03+/-1.04% and 10.59+/-0.64% for 6, 10 and 15 MV, respectively. Such ratios increase with a larger field size. For electrons the ratios are 72.59+/-1.72%, 78.52+/-2.99%, 78.89+/-2.86%, 86.08+/-2.62%. 87.75+/-1.94% and 86.33+/-3.09% for 6, 9, 12, 15, 18 and 21 MeV, respectively. They also increase with a larger size. The oblique factors also increase with larger incident angle.

Mesh:

Year:  2001        PMID: 11515663     DOI: 10.1016/s0969-8043(01)00082-3

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  8 in total

1.  Dose discrepancies in the buildup region and their impact on dose calculations for IMRT fields.

Authors:  Shu-Hui Hsu; Jean M Moran; Yu Chen; Ravi Kulasekere; Peter L Roberson
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

2.  Superficial dosimetry imaging based on Čerenkov emission for external beam radiotherapy with megavoltage x-ray beam.

Authors:  Rongxiao Zhang; Adam K Glaser; David J Gladstone; Colleen J Fox; Brian W Pogue
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

3.  Superficial dosimetry imaging of Čerenkov emission in electron beam radiotherapy of phantoms.

Authors:  Rongxiao Zhang; Colleen J Fox; Adam K Glaser; David J Gladstone; Brian W Pogue
Journal:  Phys Med Biol       Date:  2013-07-24       Impact factor: 3.609

4.  Accuracy Evaluation of Collapsed Cone Convolution Superposition Algorithms for the Nasopharynx Interface in the Early Stage of Nasopharyngeal Carcinoma.

Authors:  Yuan-Chun Lai; Li-Chung Hung; Chien-Chung Jeng; Chen-Ju Feng; Tung-Hao Chang; Shih-Ming Hsu
Journal:  Biomed Res Int       Date:  2022-05-28       Impact factor: 3.246

5.  Beam and tissue factors affecting Cherenkov image intensity for quantitative entrance and exit dosimetry on human tissue.

Authors:  Rongxiao Zhang; Adam K Glaser; Jacqueline Andreozzi; Shudong Jiang; Lesley A Jarvis; David J Gladstone; Brian W Pogue
Journal:  J Biophotonics       Date:  2016-08-10       Impact factor: 3.207

6.  Estimation of Skin doses for Retrofit Prototype Multileaf Collimators Designed for Telecobalt Therapy Machine.

Authors:  Akula Roopa Rani; Komanduri Ayyangar; A R Reddy; Ayyalasomayajula Anil Kumar; Pal Reddy Yadagiri Reddy
Journal:  J Med Phys       Date:  2021-02-02

7.  Measurement of skin surface dose distributions in radiation therapy using poly(vinyl alcohol) cryogel dosimeters.

Authors:  Molham M Eyadeh; Marcin Wierzbicki; Kevin R Diamond
Journal:  J Appl Clin Med Phys       Date:  2017-04-24       Impact factor: 2.102

8.  Skin dose during radiotherapy: a summary and general estimation technique.

Authors:  Stephen F Kry; Susan A Smith; Rita Weathers; Marilyn Stovall
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.