The measurement of photoneutrons in the vicinity of a Siemens Primus linear accelerator.

J P Lin1, T C Chu, S Y Lin, M T Liu.   

Abstract

This study involves the measurement of photoneutron contamination emitted from a Siemens Primus medical linear accelerator by using BD-PND bubble detectors. Various bubble detectors were arranged around the linac head with the interval of I m and at the same height as the isocenter to measure the dose equivalent distribution in the treatment room. The measurements were performed for 15 MV X-rays with 40 x 40cm2 and 0 x 0cm2 fields and for 15,18, and 21 MeV electrons with 25 x 25 cm2 electron cone. Neutron dose equivalent rate at the points of measurement in the treatment room decreased with increasing distance to the isocenter. The maximum neutron dose equivalents were at the isocenter, and the values for 15MV 40 x 40 and 0 x 0 cm2 were 1843+/-90 and 169.9+/-59.9 microSv per Gy X-ray, respectively. The values for 15, 18 and 21 MeV electrons with 25 x 25 cm2 cones were 100.0+/-20.4, 262.7+/-61.2 and 349.0+/-29.6 microSv per Gy electron, respectively. The neutron contamination of electrons less than 12 MeV was below the detection limit.

Entities:  

Year:  2001        PMID: 11515653     DOI: 10.1016/s0969-8043(01)00084-7

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  8 in total

Review 1.  A review on photoneutrons characteristics in radiation therapy with high-energy photon beams.

Authors:  Alireza Naseri; Asghar Mesbahi
Journal:  Rep Pract Oncol Radiother       Date:  2010-09-22

2.  Evaluating photoneutron dose equivalents for lung cancer using PMMA phantoms undergoing 15 MV IMRT.

Authors:  Hai-Bing Xu; An-Ding Dong; Mu-Tai Liu; Hsien-Chun Tseng; Chien-Yi Chen; Sung-Yi Tsai
Journal:  Technol Health Care       Date:  2022       Impact factor: 1.205

3.  Photo neutron dose equivalent rate in 15 MV X-ray beam from a Siemens Primus Linac.

Authors:  A Ghasemi; T Allahverdi Pourfallah; M R Akbari; H Babapour; M Shahidi
Journal:  J Med Phys       Date:  2015 Apr-Jun

4.  Neutron source strength measurements for Varian, Siemens, Elekta, and General Electric linear accelerators.

Authors:  David S Followill; Marilyn S Stovall; Stephen F Kry; Geoffrey S Ibbott
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

5.  Study of Photoneutron Production for the 18 MV Photon Beam of the Siemens Medical linac by Monte Carlo Simulation.

Authors:  Dowlatabadi H; Mowlavi A A; Ghorbani M; Mohammadi S; Knaup C
Journal:  J Biomed Phys Eng       Date:  2020-12-01

6.  Calculation of Photoneutron Contamination of Varian Linac in ICRU Soft-Tissue Phantom Using MCNPX Code.

Authors:  Mojtaba Cheraghian; Tayyeb Pourfallah; Amir Abbas Sabouri-Dodaran; Mehrdad Gholami
Journal:  J Med Phys       Date:  2021-08-07

7.  Management of radiation oncology patients with a pacemaker or ICD: a new comprehensive practical guideline in The Netherlands. Dutch Society of Radiotherapy and Oncology (NVRO).

Authors:  Coen W Hurkmans; Joost L Knegjens; Bing S Oei; Ad J J Maas; G J Uiterwaal; Arnoud J van der Borden; Marleen M J Ploegmakers; Lieselot van Erven
Journal:  Radiat Oncol       Date:  2012-11-24       Impact factor: 3.481

8.  Out-of-field doses and neutron dose equivalents for electron beams from modern Varian and Elekta linear accelerators.

Authors:  Carlos E Cardenas; Paige L Nitsch; Rajat J Kudchadker; Rebecca M Howell; Stephen F Kry
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102