OBJECTIVES: To compare the surgical complications and functional outcome of the Gamma nail intramedullary fixation device versus the Richards sliding hip screw and plate device in intertrochanteric femoral fractures.
DESIGN: A prospective, randomised controlled clinical trial with observer blinding.
SETTING: A regional teaching hospital in the United Kingdom. PATIENTS: All patients admitted from the local population with intertrochanteric fractured femurs were included. There were 400 patients entered into the study and 399 followed-up to one year or death. INTERVENTION: The devices were assigned by randomization to either a short-type Gamma nail (203 patients) or a Richard's-type sliding hip screw and plate (197 patients). MAIN OUTCOME MEASUREMENTS: The main surgical outcome measurements were fixation failure and reoperation. A functional outcome of pain, mobility status, and range of movement were assessed until one year.
RESULTS: The requirement for revision in the Gamma nail group was twelve (6%); for Richard's group, eight (4%). This was not statistically different (p = 0.29; odds ratio, 1.48 [0.59-3.7]). A subcapital femoral fracture occurred in the Richard's group. Femoral shaft fractures occurred with four in the Gamma nail group (2%) and none in the Richard's group (p = 0.13). Three required revision to another implant. Lag-screw cut-out occurred in eight patients in the gamma nail group (4%) and four in the Richard's group (2%). This was not statistically significant (p = 0.37; odds ratio, 2.29 [0.6-9.0]). The development of other postoperative complications was the same in both groups. There was no difference between the two groups in terms of early or long-term functional status at one year.
CONCLUSIONS: The use of an intramedullary device in the treatment of intertrochanteric femoral fractures is still associated with a higher but nonsignificant risk of postoperative complications. Routine use of the Gamma nail in this type of fracture cannot be recommended over the current standard treatment of dynamic hip screw and plate.

Entities:  

Mesh:

Year:  2001        PMID: 11514765     DOI: 10.1097/00005131-200108000-00003

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  63 in total

1.  Computational simulations of stress shielding and bone resorption around existing and computer-designed orthopaedic screws.

Authors:  A Gefen
Journal:  Med Biol Eng Comput       Date:  2002-05       Impact factor: 2.602

2.  Implant-related complications in the treatment of unstable intertrochanteric fractures: meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices.

Authors:  L Audigé; B Hanson; M F Swiontkowski
Journal:  Int Orthop       Date:  2003-05-07       Impact factor: 3.075

3.  Are short femoral nails superior to the sliding hip screw? A meta-analysis of 24 studies involving 3,279 fractures.

Authors:  Henry Wynn Jones; Philip Johnston; Martyn Parker
Journal:  Int Orthop       Date:  2006-02-22       Impact factor: 3.075

4.  A meta-analysis of the Gamma nail and dynamic hip screw in treating peritrochanteric fractures.

Authors:  Ming Liu; Zhiming Yang; Fuxing Pei; Fuguo Huang; Shiqiang Chen; Zhou Xiang
Journal:  Int Orthop       Date:  2009-04-29       Impact factor: 3.075

5.  Is distal locking of long nails for intertrochanteric fractures necessary? A clinical study.

Authors:  Bryan G Vopat; Patrick M Kane; Jeremy Truntzer; Philip McClure; David Paller; Emily Abbood; Christopher Born
Journal:  J Clin Orthop Trauma       Date:  2014-07-28

6.  Biomechanical evaluation of the risk of secondary fracture around short versus long cephalomedullary nails.

Authors:  William E Daner; John R Owen; Jennifer S Wayne; Ryan B Graves; Mark C Willis
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-06-08

7.  Intramedullary fixation of intertrochanteric hip fractures: a comparison of two implant designs.

Authors:  Nicolas E Efstathopoulos; Vassilios S Nikolaou; John T Lazarettos
Journal:  Int Orthop       Date:  2006-05-31       Impact factor: 3.075

8.  Convergence of outcomes for hip fracture fixation by nails and plates.

Authors:  Foster Chen; Zhong Wang; Timothy Bhattacharyya
Journal:  Clin Orthop Relat Res       Date:  2012-11-27       Impact factor: 4.176

9.  Surgery for fragility hip fracture-streamlining the process.

Authors:  F Leung; M Blauth; S Bavonratanavech
Journal:  Osteoporos Int       Date:  2010-11-06       Impact factor: 4.507

10.  Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation.

Authors:  George K Kouvidis; Mark B Sommers; Peter V Giannoudis; Pavlos G Katonis; Michael Bottlang
Journal:  J Orthop Surg Res       Date:  2009-05-18       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.