Wide dynamic dose range of VIPAR polymer gel dosimetry.

P Kipouros1, E Pappas, P Baras, D Hatzipanayoti, P Karaiskos, L Sakelliou, P Sandilos, I Seimenis.   

Abstract

In this work the extent of the linear dose response and the dynamic dose range of N-vinylpyrrolidone-argon based (VIPAR) polymer gels were investigated. VIPAR gels were irradiated using a 6 MV linear accelerator up to 60 Gy and a Nucletron microSelectron 192Ir HDR brachytherapy source to much higher doses to cover a dose range of two orders of magnitude. They were then MR scanned at 1.5 T to obtain T2-maps. VIPAR gel measurements obtained from the two irradiation regimes were calibrated against ion chamber measurements and dose calculations derived using the AAPM TG-43 protocol respectively. A satisfying agreement between the calibration results derived using the 6 MV x-rays and the 192Ir source was found for doses up to 60 Gy, implying that the response of the VIPAR gels is independent of photon energy and dose rate. A linear R2 dose response up to approximately 40 Gy and a dynamic dose range up to at least approximately 250 Gy were observed. VIPAR gel dose measurements derived using the monoexponentially fitted brachytherapy calibration data were found to be quite accurate.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11512616     DOI: 10.1088/0031-9155/46/8/308

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Optical scanner for 3D radiotherapy polymer gel dosimetry.

Authors:  Piotr Sobotka; Marek Kozicki; Piotr Maras; Ł Boniecki; K Kacperski; A W Domański
Journal:  Acta Phys Pol A       Date:  2012-11       Impact factor: 0.577

2.  Basic Properties of a New Polymer Gel for 3D-Dosimetry at High Dose-Rates Typical for FFF Irradiation Based on Dithiothreitol and Methacrylic Acid (MAGADIT): Sensitivity, Range, Reproducibility, Accuracy, Dose Rate Effect and Impact of Oxygen Scavenger.

Authors:  Muzafar Khan; Gerd Heilemann; Wolfgang Lechner; Dietmar Georg; Andreas Georg Berg
Journal:  Polymers (Basel)       Date:  2019-10-19       Impact factor: 4.329

3.  Mechanical and dose delivery accuracy evaluation in radiosurgery using polymer gels.

Authors:  Panagiotis Sandilos; Elias Tatsis; Lampros Vlachos; Pantelis Karaiskos; Evangelos Georgiou; Panagiotis Kipouros; Michael Torrens; Angelos Angelopoulos
Journal:  J Appl Clin Med Phys       Date:  2006-11-28       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.