Literature DB >> 11508973

Optimal focusing by spatio-temporal inverse filter. II. Experiments. Application to focusing through absorbing and reverberating media.

J F Aubry1, M Tanter, J Gerber, J L Thomas, M Fink.   

Abstract

To focus ultrasonic waves in an unknown heterogeneous medium using a phased array, one has to calculate the optimal set of signals to be applied on the transducers of the array. (In most applications of ultrasound, medical imaging, medical therapy, nondestructive testing, the first step consists of focusing a broadband ultrasound beam deeply inside the medium to be investigated.) Focusing in a homogeneous medium simply requires to compensate for the varying focus-array elements geometrical distances. Nevertheless, heterogeneities in the medium, in terms of speed of sound, density, or absorption, may strongly degrade the focusing. Different techniques have been developed in order to correct such aberrations induced by heterogeneous media (time reversal, speckle brightness, for example). In the companion to this paper, a new broadband focusing technique was investigated: the spatio-temporal inverse filter. Experimental results obtained in various media, such as reverberating and absorbing media, are presented here. In particular, intraplate echoes suppression and high-quality focusing through a human skull, as well as hyper-resolution in a reverberating medium, will be shown. It is important to notice that all these experiments were performed with fully programmable multichannel electronics whose use is required to fully exploit the spatio-temporal technique.

Entities:  

Mesh:

Year:  2001        PMID: 11508973     DOI: 10.1121/1.1377052

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  12 in total

1.  MR-guided adaptive focusing of therapeutic ultrasound beams in the human head.

Authors:  L Marsac; D Chauvet; B Larrat; M Pernot; B Robert; M Fink; A L Boch; J F Aubry; M Tanter
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

2.  MR-guided adaptive focusing of ultrasound.

Authors:  Benoît Larrat; Mathieu Pernot; Gabriel Montaldo; Mathias Fink; Mickaël Tanter
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-08       Impact factor: 2.725

Review 3.  MR-guided focused ultrasound surgery, present and future.

Authors:  David Schlesinger; Stanley Benedict; Chris Diederich; Wladyslaw Gedroyc; Alexander Klibanov; James Larner
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

4.  Transcostal high-intensity-focused ultrasound: ex vivo adaptive focusing feasibility study.

Authors:  J-F Aubry; M Pernot; F Marquet; M Tanter; M Fink
Journal:  Phys Med Biol       Date:  2008-05-12       Impact factor: 3.609

5.  Energy-based adaptive focusing of waves: application to noninvasive aberration correction of ultrasonic wavefields.

Authors:  Eric Herbert; Mathieu Pernot; Gabriel Montaldo; Mathias Fink; Mickael Tanter
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-11       Impact factor: 2.725

6.  Comparison between diffuse infrared and acoustic transmission over the human skull.

Authors:  Q Wang; N Reganti; Y Yoshioka; M Howell; G T Clement
Journal:  Proc Meet Acoust       Date:  2015-01-01

7.  Transcranial passive acoustic mapping with hemispherical sparse arrays using CT-based skull-specific aberration corrections: a simulation study.

Authors:  Ryan M Jones; Meaghan A O'Reilly; Kullervo Hynynen
Journal:  Phys Med Biol       Date:  2013-06-27       Impact factor: 3.609

8.  Simultaneous bilateral real-time 3-d transcranial ultrasound imaging at 1 MHz through poor acoustic windows.

Authors:  Brooks D Lindsey; Heather A Nicoletto; Ellen R Bennett; Daniel T Laskowitz; Stephen W Smith
Journal:  Ultrasound Med Biol       Date:  2013-02-13       Impact factor: 2.998

9.  Pitch-catch phase aberration correction of multiple isoplanatic patches for 3-D transcranial ultrasound imaging.

Authors:  Brooks D Lindsey; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-03       Impact factor: 2.725

10.  3-D transcranial ultrasound imaging with bilateral phase aberration correction of multiple isoplanatic patches: a pilot human study with microbubble contrast enhancement.

Authors:  Brooks D Lindsey; Heather A Nicoletto; Ellen R Bennett; Daniel T Laskowitz; Stephen W Smith
Journal:  Ultrasound Med Biol       Date:  2013-11-14       Impact factor: 2.998

View more