Literature DB >> 11502498

Should we use video-assisted endoscopic vein harvesting as a standard technique?

I E Rodrigus1, B Stockman, B J Amsel, A C Moulijn.   

Abstract

BACKGROUND: To investigate the feasability and results of endoscopic vein harvesting (EVH) using the Vasoview Uniport system (Guidant Corporation, Menlo Park,CA). Can this technique be used as a standard technique for vein harvesting in coronary artery bypass surgery (CABG) or is it too time consuming? Do smaller incisions result in less morbidity and discomfort?
METHODS: From October 1998 to May 1999, 158 patients who underwent CABG with venous grafts, in addition to arterial grafts, formed the study population for EVH. In group A (n=131) the vein was harvested with the Vasoview Uniport System. In group B (n=27) the vein was harvested by a conventional open technique with interrupted incisions because of unavailability of the equipment. Recordings were made on vein length, harvest time, length of incision, and complications.
RESULTS: In none of the patients in group A was a conversion to the open technique necessary. In 72/131, pure EVH was used. In 59/131 an additional incision below the knee was used for harvesting extra vein length. Mean harvested vein graft length (cm) was 35.9 (range 18-56) in group A and 30.6 (range 16-51) in group B, and mm of vein harvested/min was 77 and 71 in group A and B. Mean time for harvesting and closing (min) was 56.1 (range 14-120) SD 20.4 and 78.3 (range 37-129) SD 26 for a mean length of incision (cm) of six (range 2-19) and 27 (range 12-54). Wound complications at postoperative day three at discharge, and after six weeks were seen in 30 (23%), 27 (20%) and four (4%) patients of group A, and in five (18%), five (18%) and four (23%) of group B.
CONCLUSIONS: Despite a learning curve in using endoscopic techniques, the total procedural time for EHV is acceptable and even shorter than open harvesting. Most of the time is gained in closure of the wound. Hematoma formation is the most common peroperative complication, but diminishes with experience. The absence of postoperative edema after EVH is striking. Despite the higher costs for disposable material, we have adopted EVH as a standard technique since patient and surgeon satisfaction have improved substantially.

Entities:  

Mesh:

Year:  2001        PMID: 11502498

Source DB:  PubMed          Journal:  Heart Surg Forum        ISSN: 1098-3511            Impact factor:   0.676


  2 in total

1.  Endoscopic harvest of saphenous vein: a lesson learned from 1,348 cases.

Authors:  K-M Chiu; C-L Chen; S-H Chu; T-Y Lin
Journal:  Surg Endosc       Date:  2007-08-19       Impact factor: 4.584

2.  Immunohistochemistry comparing endoscopic vein harvesting vs. open vein harvesting on saphenous vein endothelium.

Authors:  Mohammad Hassan Nezafati; Pouya Nezafati; Sakineh Amoueian; Armin Attaranzadeh; Hamid Reza Rahimi
Journal:  J Cardiothorac Surg       Date:  2014-06-17       Impact factor: 1.637

  2 in total