Literature DB >> 11488572

An algorithm for automatic, computed-tomography-based source localization after prostate implant.

Z Li1, I A Nalcacioglu, S Ranka, S K Sahni, J R Palta, W Tomé, S Kim.   

Abstract

Permanent implant of the prostate using I-125 and Pd-103 seeds is a popular choice of treatment for early-stage prostate cancer in the United States. Evaluation of the quality of the implant is best based on the calculated dose distribution from postimplant computed tomography (CT) images. This task, however, has been time-consuming and inaccurate. We have developed an algorithm for automatic source localization from postimplant CT images. The only requirement of this algorithm is knowledge of the number of seeds present in the prostate, thus minimizing the need for human intervention. The algorithm processes volumetric CT data from the patient, and pixels of higher CT numbers are categorized into classes of definite and potential source pixels. A multithresholding technique is used to further determine the number of seeds and their precise locations in the CT volume data. A graphic user interface was developed to facilitate operator review of and intervention in the calculation and the results of the algorithm. This algorithm was tested on two phantoms containing nonradioactive seeds, one with 20 seeds in discrete locations and another with 100 seeds with small distances between seeds. The tests showed that the algorithm was able to identify the seed locations to within 1 mm of their physical locations for discrete seed locations. It was further able to separate seeds at close proximity to each other while maintaining an average seed localization error of less than 2 mm, with no operator intervention required.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11488572     DOI: 10.1118/1.1382607

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Preliminary study of correction of original metal artifacts due to 1-125 seeds in postimplant dosimetry for prostate permanent implant brachytherapy.

Authors:  Yutaka Takahashi; Shinichiro Mori; Takuyo Kozuka; Kotaro Gomi; Takayuki Nose; Takatoshi Tahara; Masahiko Oguchi; Takashi Yamashita
Journal:  Radiat Med       Date:  2006-02

2.  Reconstruction of brachytherapy seed positions and orientations from cone-beam CT x-ray projections via a novel iterative forward projection matching method.

Authors:  Damodar Pokhrel; Martin J Murphy; Dorin A Todor; Elisabeth Weiss; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

3.  Clinical application and validation of an iterative forward projection matching algorithm for permanent brachytherapy seed localization from conebeam-CT x-ray projections.

Authors:  Damodar Pokhrel; Martin J Murphy; Dorin A Todor; Elisabeth Weiss; Jeffrey F Williamson
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.