Literature DB >> 11480600

More postoperative femoral fractures with the Gamma nail than the sliding screw plate in the treatment of trochanteric fractures.

E K Osnes1, C M Lofthus, J A Falch, H E Meyer, I Stensvold, I S Kristiansen, L Nordsletten.   

Abstract

Despite several studies showing a higher incidence of peri-implant femoral fractures with the Gamma nail than with a sliding screw plate (SSP), the Gamma nail has remained the standard implant for trochanteric fractures in many hospitals. We recorded 921 trochanteric fractures in the city of Oslo during 2 years and compared the reoperation frequency in patients treated with the Gamma nail (n 379) and SSP (n 542). The distribution of age and gender in the two treatment groups was the same. 65 patients were reoperated on, several of them more than once. The only significant difference between the two surgical methods in complications leading to a reoperation was the frequency of femoral shaft fractures. 17 of the patients treated with the Gamma nail had a new femoral fracture postoperatively, compared to 3 of those with a SSP. The relative risk of another femoral fracture after surgery was 12 (95 % CI: 2.7-52) if the surgical device was a Gamma nail compared to a SSP. The Gamma nail therefore can not be recommended as the standard implant for trochanteric fractures.

Entities:  

Mesh:

Year:  2001        PMID: 11480600     DOI: 10.1080/00016470152846574

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  10 in total

1.  Proximal femoral nails compared with reverse distal femoral locking plates in intertrochanteric fractures with a compromised lateral wall; a randomised controlled trial.

Authors:  Rehan Ul Haq; Vikrant Manhas; Amite Pankaj; Amit Srivastava; Ish Kumar Dhammi; Anil Kumar Jain
Journal:  Int Orthop       Date:  2014-03-22       Impact factor: 3.075

2.  3066 consecutive Gamma Nails. 12 years experience at a single centre.

Authors:  Alicja J Bojan; Claudia Beimel; Andreas Speitling; Gilbert Taglang; Carl Ekholm; Anders Jönsson
Journal:  BMC Musculoskelet Disord       Date:  2010-06-26       Impact factor: 2.362

3.  Which implant is better for beginners to learn to treat geriatric intertrochanteric femur fractures: A randomised controlled trial of surgeons, metalwork, and patients.

Authors:  Kailun Wu; Yingjie Xu; Lei Zhang; Yong Zhang; Wu Xu; Jiaobao Chu; Nirong Bao; Qianli Ma; Huilin Yang; Jiong Jiong Guo
Journal:  J Orthop Translat       Date:  2019-12-19       Impact factor: 5.191

4.  Comparing two intramedullary devices for treating trochanteric fractures: a prospective study.

Authors:  Konstantinos G Makridis; Vasileios Georgaklis; Miltiadis Georgoussis; Vasileios Mandalos; Vasileios Kontogeorgakos; Leonidas Badras
Journal:  J Orthop Surg Res       Date:  2010-02-18       Impact factor: 2.359

5.  Consequences of hip fracture on activities of daily life and residential needs.

Authors:  E K Osnes; C M Lofthus; H E Meyer; J A Falch; L Nordsletten; I Cappelen; I S Kristiansen
Journal:  Osteoporos Int       Date:  2004-07       Impact factor: 4.507

6.  Is a sliding hip screw or im nail the preferred implant for intertrochanteric fracture fixation?

Authors:  Brian Aros; Anna N A Tosteson; Daniel J Gottlieb; Kenneth J Koval
Journal:  Clin Orthop Relat Res       Date:  2008-05-09       Impact factor: 4.176

7.  Pertrochanteric fractures: tips and tricks in nail osteosynthesis.

Authors:  A H Ruecker; J M Rueger
Journal:  Eur J Trauma Emerg Surg       Date:  2014-01-29       Impact factor: 3.693

8.  [Treatment of peri-implant refracture after intramedullary nail fixation for intertrochanteric fractures].

Authors:  Lin Teng; Yongchuan Xiao; Gang Zhong
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-03-15

9.  Complications following Treatment of Trochanteric Fractures with the Gamma3 Nail: Is the Latest Version of Gamma Nail Superior to Its Predecessor?

Authors:  Dimitrios Georgiannos; Vasilios Lampridis; Ilias Bisbinas
Journal:  Surg Res Pract       Date:  2014-02-06

10.  Intramedullary nails result in more reoperations than sliding hip screws in two-part intertrochanteric fractures.

Authors:  Kjell Matre; Leif Ivar Havelin; Jan-Erik Gjertsen; Birgitte Espehaug; Jonas Meling Fevang
Journal:  Clin Orthop Relat Res       Date:  2012-12-07       Impact factor: 4.176

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.