Literature DB >> 11476935

Low-reflection-coefficient liquid interfaces for system characterization.

T J Hall1, E L Madsen, F Dong, I R Medina, G R Frank.   

Abstract

The use of liquid brominated hydrocarbons to form a planar reflecting interface with water is described. Gravity-based planar reflecting surfaces with known reflection coefficients can be used in system characterization for quantitative ultrasonics, and a set of surfaces with a range of reflection coefficients allows calibration of the output power and receiver gain of ultrasonic imaging systems. The substances reported here are immiscible in water and form interfaces with water, resulting in a broad range of acoustic reflection coefficients. Reflection coefficients were measured at temperatures from 18-24 degrees C for "pure" substances and for mixtures of two brominated hydrocarbons. Results show that reflection coefficients are weakly dependent on temperature and that, at a specific temperature, a significant range of arbitrarily small reflection coefficients is available, in the case of the mixtures, by the appropriate choice of weight-percents of the two brominated hydrocarbons.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11476935     DOI: 10.1016/s0301-5629(01)00391-x

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  5 in total

1.  Noninvasive, quantitative, spatiotemporal characterization of mineralization in three-dimensional collagen hydrogels using high-resolution spectral ultrasound imaging.

Authors:  Madhu Gudur; Rameshwar R Rao; Yi-Sing Hsiao; Alexis W Peterson; Cheri X Deng; Jan P Stegemann
Journal:  Tissue Eng Part C Methods       Date:  2012-07-16       Impact factor: 3.056

2.  Ultrasonic tissue characterization via 2-D spectrum analysis: theory and in vitro measurements.

Authors:  Tian Liu; Frederic L Lizzi; Jeffrey A Ketterling; Ronald H Silverman; Gerald J Kutcher
Journal:  Med Phys       Date:  2007-03       Impact factor: 4.071

3.  Absolute backscatter coefficient estimates of tissue-mimicking phantoms in the 5-50 MHz frequency range.

Authors:  Matthew M McCormick; Ernest L Madsen; Meagan E Deaner; Tomy Varghese
Journal:  J Acoust Soc Am       Date:  2011-08       Impact factor: 1.840

4.  High-frequency ultrasound m-mode imaging for identifying lesion and bubble activity during high-intensity focused ultrasound ablation.

Authors:  Ronald E Kumon; Madhu S R Gudur; Yun Zhou; Cheri X Deng
Journal:  Ultrasound Med Biol       Date:  2012-02-15       Impact factor: 2.998

5.  Fluorescence response of human HER2+ cancer- and MCF-12F normal cells to 200MHz ultrasound microbeam stimulation: a preliminary study of membrane permeability variation.

Authors:  Jae Youn Hwang; Jungwoo Lee; Changyang Lee; Anette Jakob; Robert Lemor; Lali K Medina-Kauwe; K Kirk Shung
Journal:  Ultrasonics       Date:  2012-03-29       Impact factor: 2.890

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.