Literature DB >> 11476792

Comparison of several one-step home urinary luteinizing hormone detection test kits to OvuQuick.

M S Nielsen1, S D Barton, H H Hatasaka, J B Stanford.   

Abstract

OBJECTIVE: To compare clinical accuracy and ease of use for several of the new rapid one-step home urinary LH detection kits compared with the preexisting OvuQuick brand LH detection kit (designated as the standard).
DESIGN: Prospective cohort study.
SETTING: University-based infertility clinic. PATIENT(S): All women undergoing intrauterine inseminations at the clinic, regardless of infertility diagnosis, were offered enrollment during a 28-month study period. INTERVENTION(S): Each participant was supplied three one-step test kits (OvuQuick One-Step, ClearPlan Easy, and SureStep) in addition to a multistep OvuQuick test kit and instructed to run the tests in parallel on the same urine sample and to record the results. Urine testing was performed every 12 hours, beginning 3 days before the anticipated onset of an LH surge, and continued with the one-step kits every 12 hours for 48 hours after the surge was first detected by OvuQuick. Subjects also completed questionnaires evaluating the use of each test kit. MAIN OUTCOME MEASURE(S): Correlation of LH surge detection by one-step kits in comparison to surge detection by OvuQuick. Satisfaction and ease of use questionnaires. RESULT(S): Sixty-three volunteers returned useable data, from which 81 evaluable cycles were analyzed. The majority of patients found the newer one-step kits to be easier to use and less time consuming than OvuQuick. The three one-step kits detected the LH surge within +/- one testing period (+/-12 hours) of detection by OvuQuick 68%-84% of the time. OvuQuick One-Step, with modified instructions allowing for an equal color intensity in the test and reference areas, had the highest correlation with OvuQuick (84%). However, with a study power (alpha = 0.05, beta = 0.10) sufficient to detect a 10% difference between Ovuquick and each one-step kit, all one-step kits were statistically equivalent to each other. There was no cycle in which a one-step kit detected a positive LH surge but OvuQuick did not. CONCLUSION(S): One-step urinary LH kits are easier for patients to use than a multistep home urinary LH kit and have reasonable correlation with the multistep kit when used clinically for timing artificial inseminations.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11476792     DOI: 10.1016/s0015-0282(01)01881-7

Source DB:  PubMed          Journal:  Fertil Steril        ISSN: 0015-0282            Impact factor:   7.329


  9 in total

1.  Natural procreative technology for infertility and recurrent miscarriage: outcomes in a Canadian family practice.

Authors:  Elizabeth Tham; Karen Schliep; Joseph Stanford
Journal:  Can Fam Physician       Date:  2012-05       Impact factor: 3.275

Review 2.  Home testing past, present and future: lessons learned and implications for HIV home tests.

Authors:  Mobolaji Ibitoye; Timothy Frasca; Rebecca Giguere; Alex Carballo-Diéguez
Journal:  AIDS Behav       Date:  2014-05

3.  The impact of menstrual cycle phase on cardiac autonomic regulation.

Authors:  Paula S McKinley; Arlene R King; Peter A Shapiro; Iordan Slavov; Yixin Fang; Ivy S Chen; Larry D Jamner; Richard P Sloan
Journal:  Psychophysiology       Date:  2009-04-06       Impact factor: 4.016

4.  Assessment of anovulation in eumenorrheic women: comparison of ovulation detection algorithms.

Authors:  Kristine E Lynch; Sunni L Mumford; Karen C Schliep; Brian W Whitcomb; Shvetha M Zarek; Anna Z Pollack; Elizabeth R Bertone-Johnson; Michelle Danaher; Jean Wactawski-Wende; Audrey J Gaskins; Enrique F Schisterman
Journal:  Fertil Steril       Date:  2014-05-27       Impact factor: 7.329

5.  Pilot test and validation of the peak day method of prospective determination of ovulation against a handheld urine hormone monitor.

Authors:  Christina A Porucznik; Kyley J Cox; Karen C Schliep; Joseph B Stanford
Journal:  BMC Womens Health       Date:  2014-01-08       Impact factor: 2.809

6.  Reclaiming fertility awareness methods to inform timed intercourse for HIV serodiscordant couples attempting to conceive.

Authors:  Caiyun Liao; Maybel Wahab; Jean Anderson; Jenell S Coleman
Journal:  J Int AIDS Soc       Date:  2015-01-09       Impact factor: 5.396

7.  Urinary Luteinizing Hormone Tests: Which Concentration Threshold Best Predicts Ovulation?

Authors:  Rene Antonio Leiva; Thomas Paul Bouchard; Saman Hasan Abdullah; René Ecochard
Journal:  Front Public Health       Date:  2017-11-28

Review 8.  Prospective pregnancy study designs for assessing reproductive and developmental toxicants.

Authors:  Germaine M Buck; Courtney D Lynch; Joseph B Stanford; Anne M Sweeney; Laura A Schieve; John C Rockett; Sherry G Selevan; Steven M Schrader
Journal:  Environ Health Perspect       Date:  2004-01       Impact factor: 9.031

Review 9.  The value of home-based collection of biospecimens in reproductive epidemiology.

Authors:  John C Rockett; Germaine M Buck; Courtney D Lynch; Sally D Perreault
Journal:  Environ Health Perspect       Date:  2004-01       Impact factor: 9.031

  9 in total