Literature DB >> 11463119

Automated detection of malaria pigment in white blood cells for the diagnosis of malaria in Portugal.

T Hänscheid1, J Melo-Cristino, B G Pinto.   

Abstract

A novel automated method (Cell-Dyn 3500) allows malaria diagnosis by detecting malaria pigment in white blood cells during routine full blood counts. In Portugal, 174 samples from 148 patients who presented to the emergency department were analyzed. Compared with microscopy the sensitivity was 95% and the specificity was 88%. In 5 cases, false-positive Cell-Dyn 3500 results were from patients who had a recent history of treated malaria, indicating that the method may remain positive during convalescence. Six patients were diagnosed due to the changes observed with the automated method only, because clinicians had not requested malaria smears. This instrument appears to provide a promising method for the diagnosis of malaria, especially where automated full blood counts are routine in the work-up of febrile patients.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11463119     DOI: 10.4269/ajtmh.2001.64.290

Source DB:  PubMed          Journal:  Am J Trop Med Hyg        ISSN: 0002-9637            Impact factor:   2.345


  10 in total

1.  Poor accuracy of rapid diagnostic tests and misdiagnosis of imported malaria: are PCR-based reference laboratories the answer?

Authors:  Thomas Hänscheid; Emilia Valadas
Journal:  J Clin Microbiol       Date:  2002-02       Impact factor: 5.948

2.  Automated detection of malaria-associated pseudoeosinophilia and abnormal WBC scattergram by the Sysmex XE-2100 hematology analyzer: a clinical study with 1,801 patients and real-time quantitative PCR analysis in vivax malaria-endemic area.

Authors:  Jong-Ha Yoo; Jaewoo Song; Kyung-A Lee; Young-Kyu Sun; Young-Ah Kim; Tae Sung Park; Jong Rak Choi
Journal:  Am J Trop Med Hyg       Date:  2010-03       Impact factor: 2.345

3.  Detection of intracellular parasites by use of the CellaVision DM96 analyzer during routine screening of peripheral blood smears.

Authors:  Lori D Racsa; Rita M Gander; Paul M Southern; Erin McElvania TeKippe; Christopher Doern; Hung S Luu
Journal:  J Clin Microbiol       Date:  2014-11-05       Impact factor: 5.948

Review 4.  Methodology and application of flow cytometry for investigation of human malaria parasites.

Authors:  Brian T Grimberg
Journal:  J Immunol Methods       Date:  2011-02-04       Impact factor: 2.303

5.  Detection of imported malaria with the Cell-Dyn 4000 hematology analyzer.

Authors:  Peter C Wever; Yvonne M C Henskens; Piet A Kager; Jacob Dankert; Tom van Gool
Journal:  J Clin Microbiol       Date:  2002-12       Impact factor: 5.948

Review 6.  Loop-mediated isothermal amplification (LAMP) assay for the diagnosis of imported malaria: a narrative review.

Authors:  Spinello Antinori; Anna Lisa Ridolfo; Romualdo Grande; Laura Galimberti; Giacomo Casalini; Andrea Giacomelli; Laura Milazzo
Journal:  Infez Med       Date:  2021-09-10

Review 7.  Malaria diagnosis: a brief review.

Authors:  Noppadon Tangpukdee; Chatnapa Duangdee; Polrat Wilairatana; Srivicha Krudsood
Journal:  Korean J Parasitol       Date:  2009-05-26       Impact factor: 1.341

Review 8.  Automated haematology analysis to diagnose malaria.

Authors:  Germán Campuzano-Zuluaga; Thomas Hänscheid; Martin P Grobusch
Journal:  Malar J       Date:  2010-11-30       Impact factor: 2.979

9.  Full blood count and haemozoin-containing leukocytes in children with malaria: diagnostic value and association with disease severity.

Authors:  Thomas Hänscheid; Matthias Längin; Bertrand Lell; Marc Pötschke; Sunny Oyakhirome; Peter G Kremsner; Martin P Grobusch
Journal:  Malar J       Date:  2008-06-12       Impact factor: 2.979

10.  A diagnostic tool for malaria based on computer software.

Authors:  Manas Kotepui; Kwuntida Uthaisar; Bhukdee Phunphuech; Nuoil Phiwklam
Journal:  Sci Rep       Date:  2015-11-12       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.