Performance assessment of the Gulmay D3300 kilovoltage X-ray therapy unit.

P A Evans1, A J Moloney, P J Mountford.   

Abstract

A performance assessment was made of the Gulmay D3300 kilovoltage (combined superficial and orthovoltage) X-ray therapy unit. Results are presented for the key dosimetric beam parameters required for routine patient treatment. This unit is relatively new to the UK market and displayed similar properties to other existing equipment. Beam half-value layers were different from comparable published data, but were consistent with the actual values of external tube filtration employed. The applicator, system interlocks and dose monitor performance were satisfactory and the tube leakage was below the UK recommended maximum (air kerma rate 300 mGy h(-1) at 5 cm from the tube head). The variation of absorbed dose with stand-off distance from the applicator base followed the inverse-square law for all tested combinations of beam tube potential (kVp) and applicator, and the measured focus-to-surface distances were in acceptable agreement with the nominal values. A significant beam profile asymmetry was seen for field sizes greater than 10 cm at the upper tube potential (kVp) range (maximum ionization quotient 1.08), but this was an inherent property of the X-ray tube. The difficulties of obtaining percentage depth dose measurements are discussed, and it was concluded that the use of published data (appropriately verified) was acceptable. The methodology followed could form the basis of an acceptance and commissioning protocol. To address the relative lack of agreed standards for this type of equipment, performance test tolerances are proposed that are recommended for new installations.

Entities:  

Mesh:

Year:  2001        PMID: 11459733     DOI: 10.1259/bjr.74.882.740537

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  7 in total

1.  Acceptance, commissioning and clinical use of the WOmed T-200 kilovoltage X-ray therapy unit.

Authors:  Maria M Aspradakis; Paolo Zucchetti
Journal:  Br J Radiol       Date:  2015-07-30       Impact factor: 3.039

2.  Characterization of an orthovoltage biological irradiator used for radiobiological research.

Authors:  Rezvan Azimi; Parham Alaei; Emiliano Spezi; Susanta K Hui
Journal:  J Radiat Res       Date:  2015-02-17       Impact factor: 2.724

3.  Dosimetric characteristics of a new unit for electronic skin brachytherapy.

Authors:  Teresa Garcia-Martinez; Jan-Pieter Chan; Jose Perez-Calatayud; Facundo Ballester
Journal:  J Contemp Brachytherapy       Date:  2014-02-19

4.  Role of in vivo dosimetry with radiochromic films for dose verification during cutaneous radiation therapy.

Authors:  Hong-Wei Liu; James Gräfe; Rao Khan; Ivo Olivotto; J Eduardo Villarreal Barajas
Journal:  Radiat Oncol       Date:  2015-01-10       Impact factor: 3.481

5.  Modeling a superficial radiotherapy X-ray source for relative dose calculations.

Authors:  Christopher D Johnstone; Richard LaFontaine; Yannick Poirier; Mauro Tambasco
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102

6.  Off-axis dose distribution with stand-in and stand-off configurations for superficial radiotherapy treatments.

Authors:  Keith Davey; Margaret Moore; Sinéad Cleary; Christoph Kleefeld; Mark J Foley
Journal:  J Appl Clin Med Phys       Date:  2019-10-12       Impact factor: 2.102

7.  Assessing the deviation from the inverse square law for orthovoltage beams with closed-ended applicators.

Authors:  James Gräfe; Yannick Poirier; Ferenc Jacso; Rao Khan; Hong-Wei Liu; J Eduardo Villarreal-Barajas
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.