Literature DB >> 11458569

Experimental determination of the diffusion coefficient in two-dimensions in ferrous sulphate gels using the finite element method.

C Baldock1, P J Harris, A R Piercy, B Healy.   

Abstract

A novel two-dimensional finite element method for modelling the diffusion which occurs in Fricke or ferrous sulphate type radiation dosimetry gels is presented. In most of the previous work, the diffusion coefficient has been estimated using simple one-dimensional models. This work presents a two-dimensional model which enables the diffusion coefficient to be determined in a much wider range of experimental situations. The model includes the provision for the determination of a drift parameter. To demonstrate the technique comparative diffusion measurements between ferrous sulphate radiation dosimetry gels, with and without xylenol orange chelating agent and carbohydrate additives have been undertaken. Diffusion coefficients of 9.7 +/- 0.4, 13.3 +/- 0.6 and 9.5 +/- 0.8 10(-3) cm2h-1 were determined for ferrous sulphate radiation dosimetry gels with and without xylenol orange and with xylenol orange and sucrose additives respectively.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11458569     DOI: 10.1007/BF03178282

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  11 in total

1.  Optical-CT gel-dosimetry I: basic investigations.

Authors:  Mark Oldham; Jeffrey H Siewerdsen; Sai Kumar; John Wong; David A Jaffray
Journal:  Med Phys       Date:  2003-04       Impact factor: 4.071

2.  Characterization of a new radiochromic three-dimensional dosimeter.

Authors:  P Y Guo; J A Adamovics; M Oldham
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

3.  A practical three-dimensional dosimetry system for radiation therapy.

Authors:  Pengyi Guo; John Adamovics; Mark Oldham
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

4.  Sensitivity calibration procedures in optical-CT scanning of BANG 3 polymer gel dosimeters.

Authors:  Y Xu; Cheng-Shie Wuu; Marek J Maryanski
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

Review 5.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

6.  Optimization of the imaging protocol of an X-ray CT scanner for evaluation of normoxic polymer gel dosimeters.

Authors:  Brindha Subramanian; Paul B Ravindran; Clive Baldock
Journal:  J Med Phys       Date:  2006-04

7.  Small field dose delivery evaluations using cone beam optical computed tomography-based polymer gel dosimetry.

Authors:  Timothy Olding; Oliver Holmes; Paul Dejean; Kim B McAuley; Ken Nkongchu; Giles Santyr; L John Schreiner
Journal:  J Med Phys       Date:  2011-01

Review 8.  Detection of therapeutic radiation in three-dimensions.

Authors:  John A Adamovics
Journal:  Beilstein J Org Chem       Date:  2017-07-05       Impact factor: 2.883

9.  Study of Ag Nanoparticles in a Polyacrylamide Hydrogel Dosimeters by Optical Technique.

Authors:  Yasser S Soliman; Soad M Tadros; Wafaa B Beshir; Gamal R Saad; Salvatore Gallo; Laila I Ali; Magdi M Naoum
Journal:  Gels       Date:  2022-04-05

10.  Different Dosimeters/Detectors Used in Small-Field Dosimetry: Pros and Cons.

Authors:  Wrya Parwaie; Soheila Refahi; Mahdieh Afkhami Ardekani; Bagher Farhood
Journal:  J Med Signals Sens       Date:  2018 Jul-Sep
View more