Wear of HIPed and non-HIPed alumina-alumina hip joints under standard and severe simulator testing conditions.

J E Nevelos1, E Ingham, C Doyle, A B Nevelos, J Fisher.   

Abstract

Wear and the biological response to wear debris of artificial joints remain major concerns in total hip arthroplasty (THA). The long-term effects of UHMWPE wear debris are well documented and these have led to interest in alternate bearing materials for THA. Alumina ceramic-ceramic hip joints have been successfully used for more than 30 years with low wear and little incidence of osteolysis. The most common wear pattern observed on retrieved components is an elliptical wear 'stripe' on the heads and a corresponding worn area on the cup with an approximated wear rate of 1-5 mm3 pa. More severe wear has also occasionally occurred, usually in association with an abnormal clinical history. Modern alumina-alumina THAs use an improved HIPed (hot isostatically pressed) alumina ceramic-bearing material which may be more resistant to severe wear. Previous in vitro simulator studies have not replicated in vivo wear rates or mechanisms. The aim of this study was to compare previous generation non-HIPed alumina and modern HIPed alumina in a hip joint simulator under 'normal' and 'harsh' testing conditions. HIPed alumina was found to have a lower wear rate than non-HIPed alumina, although the difference was not statistically significant at the 95% confidence level. Testing in Gelofusine and water lubricants did not elevate the wear rates of either material. Elevated swing phase load testing also had no significant effect on the wear rates of either material. Testing in the absence of any lubricant produced very severe wear of the non-HIPed material in one specimen only.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11456058     DOI: 10.1016/s0142-9612(00)00361-6

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  6 in total

1.  Control of surface morphology of carbide coating on Co-Cr-Mo implant alloy.

Authors:  N S Vandamme; L D T Topoleski
Journal:  J Mater Sci Mater Med       Date:  2005-07       Impact factor: 3.896

Review 2.  [Implant wear and aseptic loosening. An overview].

Authors:  C Kaddick; I Catelas; P H Pennekamp; M A Wimmer
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

3.  Squeaking and microcracks in a delta-delta ceramic coupling: pin-on-disc study.

Authors:  Kiyokazu Fukui; Ayumi Kaneuji; Tadami Matsumoto; Kazuhiro Shintani
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-03-12

Review 4.  Review on squeaking hips.

Authors:  Yadin David Levy; Selin Munir; Shane Donohoo; William Lindsay Walter
Journal:  World J Orthop       Date:  2015-11-18

5.  Effect of femoral head size on the wear of metal on metal bearings in total hip replacements under adverse edge-loading conditions.

Authors:  Mazen Al-Hajjar; John Fisher; Sophie Williams; Joanne L Tipper; Louise M Jennings
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2012-12-20       Impact factor: 3.368

6.  Wear of composite ceramics in mixed-material combinations in total hip replacement under adverse edge loading conditions.

Authors:  Mazen Al-Hajjar; Silvia Carbone; Louise M Jennings; Sabine Begand; Thomas Oberbach; Daniel Delfosse; John Fisher
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2016-04-08       Impact factor: 3.368

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.