Evaluation of different recording parameters to establish a standard for flash electroretinography in rodents.

A U Bayer1, P Cook, S E Brodie, K P Maag, T Mittag.   

Abstract

Different electrodes and stimulus protocols commonly used for electroretinography in rodent eyes were compared for convenience of use, degree of damage to corneal epithelium, and for magnitude of amplitude, reproducibility, left versus right eye accuracy, and reliability of recorded parameters of the flash electroretinogram (ERG). Adult C57BL/6 pigmented mice and albino Wistar rats were used to determine scotopic ERGs in response to Ganzfeld or strobe-light stimulation and light-adapted (photopic) ERGs recorded from both eyes at the same time. Test-retest data were used for statistical analyses to compare a monopolar gold-wire contact lens electrode (CLE), a cotton-wick silver-silver chloride electrode (CSCE), a DTL fiber electrode (DTLE), and a circular stainless steel wire electrode (SSE). Corneas were evaluated for abrasion after ERG recordings using fluorescein staining and also for the time taken, ease of insertion, and re-insertions required for the different electrodes. Compared to CSCE, DTLE, and SSE, the ERG potentials recorded by CLE had significantly larger scotopic amplitudes and oscillatory potentials under strobe or Ganzfeld stimulation and for light-adapted ERG b-wave amplitudes in both mice and rats. In analyzing test-retest data of scotopic ERG a-wave and b-wave amplitudes, the intraclass correlation coefficient showed the best agreement for the CLE (range 0.61-0.94) compared to the SSE (0.13-0.77), DTLE (0.02-0.69), and CSCE (0.12-0.51). In mice and rats, logistic regression analyses revealed significant correlations for amplitudes of most scotopic ERG parameters between contralateral eyes obtained with CLE and for some ERG components recorded by SSE. When comparing ERG amplitudes for stimulation by strobe or Ganzfeld, the difference was least with the CLE compared to DTLE, CSCE, or SSE. The time taken to insert the four different electrodes was greatest for the CLE in both mice and rats. The extent of corneal abrasion resulting from electrode use in mice was largest for the SSE followed by the CLE. However, in rats there was almost no corneal damage after ERG recordings with the CLE. Because of the stability of eye contact, the CLE allows ERGs to be determined over a longer recording session. Recording of scotopic and photopic (light-adapted) ERGs in rodents with monopolar gold-wire contact lens electrodes provides greater amplitudes and higher reproducibility when compared to other commonly used corneal electrodes. These electrodes are significantly better overall than others that were evaluated and should be considered for a standard protocol to monitor retinal function in rodent eyes.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11448710     DOI: 10.1016/s0042-6989(01)00103-1

Source DB:  PubMed          Journal:  Vision Res        ISSN: 0042-6989            Impact factor:   1.886


  17 in total

Review 1.  Recommendations for a toxicological screening ERG procedure in laboratory animals.

Authors:  Serge G Rosolen; Florence Rigaudière; Jean-François Le Gargasson; Mitchell G Brigell
Journal:  Doc Ophthalmol       Date:  2005-01       Impact factor: 2.379

2.  Using the Electroretinogram to Assess Function in the Rodent Retina and the Protective Effects of Remote Limb Ischemic Preconditioning.

Authors:  Alice Brandli; Jonathan Stone
Journal:  J Vis Exp       Date:  2015-06-09       Impact factor: 1.355

3.  Test-retest reliability of scotopic full-field electroretinograms in rabbits.

Authors:  Jan Luebke; Alexandra Anton; Michael Bach
Journal:  Doc Ophthalmol       Date:  2017-03-16       Impact factor: 2.379

4.  Effective and sustained delivery of hydrophobic retinoids to photoreceptors.

Authors:  Peter H Tang; Jie Fan; Patrice W Goletz; Lee Wheless; Rosalie K Crouch
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-06-23       Impact factor: 4.799

5.  Deletion of GRK1 causes retina degeneration through a transducin-independent mechanism.

Authors:  Jie Fan; Keisuke Sakurai; Ching-Kang Chen; Baerbel Rohrer; Bill X Wu; King-Wai Yau; Vladimir Kefalov; Rosalie K Crouch
Journal:  J Neurosci       Date:  2010-02-17       Impact factor: 6.167

6.  Improved contact lens electrode for corneal ERG recordings in mice.

Authors:  Botir T Sagdullaev; Paul J DeMarco; Maureen A McCall
Journal:  Doc Ophthalmol       Date:  2004-05       Impact factor: 2.379

7.  An adaptive ERG technique to measure normal and altered dark adaptation in the mouse.

Authors:  Paul J DeMarco; Yoshiaki Katagiri; Volker Enzmann; Henry J Kaplan; Maureen A McCall
Journal:  Doc Ophthalmol       Date:  2007-09-22       Impact factor: 2.379

8.  Isorhodopsin rather than rhodopsin mediates rod function in RPE65 knock-out mice.

Authors:  Jie Fan; Baerbel Rohrer; Gennadiy Moiseyev; Jian-Xing Ma; Rosalie K Crouch
Journal:  Proc Natl Acad Sci U S A       Date:  2003-10-24       Impact factor: 11.205

9.  Isoflurane is an effective alternative to ketamine/xylazine/acepromazine as an anesthetic agent for the mouse electroretinogram.

Authors:  William R Woodward; Dongseok Choi; Jared Grose; Bojan Malmin; Sawan Hurst; Jiaqing Pang; Richard G Weleber; De-Ann M Pillers
Journal:  Doc Ophthalmol       Date:  2007-09-21       Impact factor: 2.379

10.  Paradoxical role of BDNF: BDNF+/- retinas are protected against light damage-mediated stress.

Authors:  R Brooks Wilson; Kannan Kunchithapautham; Bärbel Rohrer
Journal:  Invest Ophthalmol Vis Sci       Date:  2007-06       Impact factor: 4.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.