A finite element analysis of hollow stemmed hip prostheses as a means of reducing stress shielding of the femur.

S Gross1, E W Abel.   

Abstract

Stress shielding of the femur is known to be a principal factor in aseptic loosening of hip replacements. This paper considers the use of a hollow stemmed hip implant for reducing the effects of stress shielding, while maintaining acceptably low levels of stress in the cement. Using finite element modelling, the stresses in the proximal femur using different shapes of hollow stem were compared with those produced using comparable sizes of solid stem with different values of elastic modulus. A reduction in stress shielding could be achieved with a hollow stem. A cylindrical hollow stem design was then optimised in order to control the maximum allowable stress in the cement, the minimum allowable stresses in the bone, and a combination of the two. The resulting stems achieved an increase in proximal bone stress of about 15% for the first case and 32% for a model using high strength cement, compared with solid stems of the same nominal outside diameter. The gains of these theoretically optimised designs dropped off rapidly further down the stem. Linearly tapered hollow stems reached a 22% gain, which could be a good compromise between acceptable cement stresses and ease of manufacture.

Mesh:

Year:  2001        PMID: 11448691     DOI: 10.1016/s0021-9290(01)00072-0

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  16 in total

1.  MyHip: supporting planning and surgical guidance for a better total hip arthroplasty : A pilot study.

Authors:  Jérôme Schmid; Christophe Chênes; Sylvain Chagué; Pierre Hoffmeyer; Panayiotis Christofilopoulos; Massimiliano Bernardoni; Caecilia Charbonnier
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-01       Impact factor: 2.924

Review 2.  New Developments of Ti-Based Alloys for Biomedical Applications.

Authors:  Yuhua Li; Chao Yang; Haidong Zhao; Shengguan Qu; Xiaoqiang Li; Yuanyuan Li
Journal:  Materials (Basel)       Date:  2014-03-04       Impact factor: 3.623

3.  Evaluating the Effect of Minimizing Screws on Stabilization of Symphysis Mandibular Fracture by 3D Finite Element Analysis.

Authors:  Ghias Kharmanda; Mohamed-Yaser Kharma
Journal:  J Maxillofac Oral Surg       Date:  2016-04-21

4.  Evaluation of ranges of motion of a new constrained acetabular prosthesis for canine total hip replacement.

Authors:  Ching-Ho Wu; Cheng-Chung Lin; Tung-Wu Lu; Sheng-Mao Hou; Chih-Chung Hu; Lih-Seng Yeh
Journal:  Biomed Eng Online       Date:  2013-11-10       Impact factor: 2.819

5.  Influence of PEEK Coating on Hip Implant Stress Shielding: A Finite Element Analysis.

Authors:  Jesica Anguiano-Sanchez; Oscar Martinez-Romero; Hector R Siller; Jose A Diaz-Elizondo; Eduardo Flores-Villalba; Ciro A Rodriguez
Journal:  Comput Math Methods Med       Date:  2016-03-14       Impact factor: 2.238

6.  Bone preserving level of osteotomy in short-stem total hip arthroplasty does not influence stress shielding dimensions - a comparing finite elements analysis.

Authors:  Rene Burchard; Sabrina Braas; Christian Soost; Jan Adriaan Graw; Jan Schmitt
Journal:  BMC Musculoskelet Disord       Date:  2017-08-07       Impact factor: 2.362

7.  Minimizing Stress Shielding and Cement Damage in Cemented Femoral Component of a Hip Prosthesis through Computational Design Optimization.

Authors:  Abdellah Ait Moussa; Justin Fischer; Rohan Yadav; Morshed Khandaker
Journal:  Adv Orthop       Date:  2017-02-28

8.  Comparison of various functionally graded femoral prostheses by finite element analysis.

Authors:  Azim Ataollahi Oshkour; Hossein Talebi; Seyed Farid Seyed Shirazi; Mehdi Bayat; Yat Huang Yau; Faris Tarlochan; Noor Azuan Abu Osman
Journal:  ScientificWorldJournal       Date:  2014-08-27

9.  Current Trends in Metallic Orthopedic Biomaterials: From Additive Manufacturing to Bio-Functionalization, Infection Prevention, and Beyond.

Authors:  Amir A Zadpoor
Journal:  Int J Mol Sci       Date:  2018-09-10       Impact factor: 5.923

10.  Finite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions.

Authors:  Chethan K N; Shyamasunder Bhat N; Zuber M; Satish Shenoy B
Journal:  J Biomed Phys Eng       Date:  2019-10-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.