Literature DB >> 11443461

Evaluation of a head-mounted display (HMD) in the performance of a simulated laparoscopic task.

W K Cheah1, J E Lenzi, J So, F Dong, C K Kum, P Goh.   

Abstract

BACKGROUND: Head-mounted display (HM) units are used in various industries, but they have been tried only recently in surgery. In this study, we evaluated whether a commercially available HMD would improve or impede a laparoscopic task-in this case, suturing.
METHODS: Six participants performed a total of 120 laparoscopic suture knots in an experimental model. The Olympus FMD011 model with a two-dimensional image was used. The order of each task with or without the head display unit was random. The time to complete each knot was recorded, and the results were analyzed.
RESULTS: The display unit prolonged the suturing times of the subjects by 10% (p < 0.04).
CONCLUSIONS: In this experimental model, the HMD we utilized did not appear to improve laparoscopic suturing. More developments, such as improved depth perception and better resolution, may increase its usefulness for laparoscopic tasks.

Entities:  

Mesh:

Year:  2001        PMID: 11443461     DOI: 10.1007/s004640090026

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  5 in total

1.  The visual effects of head-mounted display (HMD) are not distinguishable from those of desk-top computer display.

Authors:  E Peli
Journal:  Vision Res       Date:  1998-06       Impact factor: 1.886

2.  Stereoscopic head-mounted display incorporated into microsurgical procedures: technical note.

Authors:  M L Levy; J C Chen; K Moffitt; Z Corber; J G McComb
Journal:  Neurosurgery       Date:  1998-08       Impact factor: 4.654

3.  Head-mounted video monitor for global visual access in mini-invasive surgery. An initial report.

Authors:  W P Geis
Journal:  Surg Endosc       Date:  1996-07       Impact factor: 4.584

4.  Three-dimensional versus two-dimensional imaging for laparoscopic suturing.

Authors:  C K Kum; P Goh; D J Alexander; S Moochala
Journal:  Br J Surg       Date:  1997-01       Impact factor: 6.939

5.  Robotic arm enhancement to accommodate improved efficiency and decreased resource utilization in complex minimally invasive surgical procedures.

Authors:  W P Geis; H C Kim; E J Brennan; P C McAfee; Y Wang
Journal:  Stud Health Technol Inform       Date:  1996
  5 in total
  9 in total

1.  The benefits of stereoscopic vision in robotic-assisted performance on bench models.

Authors:  Y Munz; K Moorthy; A Dosis; J D Hernandez; S Bann; F Bello; S Martin; A Darzi; T Rockall
Journal:  Surg Endosc       Date:  2004-02-02       Impact factor: 4.584

2.  Dexterity enhancement with robotic surgery.

Authors:  K Moorthy; Y Munz; A Dosis; J Hernandez; S Martin; F Bello; T Rockall; A Darzi
Journal:  Surg Endosc       Date:  2004-04-06       Impact factor: 4.584

Review 3.  Possibilities and limitations of current stereo-endoscopy.

Authors:  U D A Mueller-Richter; A Limberger; P Weber; K W Ruprecht; W Spitzer; M Schilling
Journal:  Surg Endosc       Date:  2004-04-27       Impact factor: 4.584

4.  Commentary. Regarding the article "three dimensional view in endoscopic surgery" by N. Ishikawa et al.

Authors:  G Berci
Journal:  Surg Endosc       Date:  2004-06-29       Impact factor: 4.584

5.  Simulated laparoscopy using a head-mounted display vs traditional video monitor: an assessment of performance and muscle fatigue.

Authors:  S K Maithel; L Villegas; N Stylopoulos; S Dawson; D B Jones
Journal:  Surg Endosc       Date:  2004-12-23       Impact factor: 4.584

6.  Advantages of advanced laparoscopic systems.

Authors:  J Heemskerk; R Zandbergen; J G Maessen; J W M Greve; N D Bouvy
Journal:  Surg Endosc       Date:  2006-03-09       Impact factor: 4.584

7.  3D presentation in surgery: a review of technology and adverse effects.

Authors:  Tianqi Wang; Bin Zheng
Journal:  J Robot Surg       Date:  2018-12-15

8.  Gravity line strategy may reduce risks of intraoperative injury during laparoscopic surgery.

Authors:  Anlong Zhu; Chao Yuan; Daxun Piao; Tao Jiang; Hongchi Jiang
Journal:  Surg Endosc       Date:  2013-07-27       Impact factor: 4.584

9.  [Not Available].

Authors:  James G Bittner; Christopher A Hathaway; James A Brown
Journal:  J Minim Access Surg       Date:  2008-04       Impact factor: 1.407

  9 in total