Backscatter dose from metallic materials due to obliquely incident high-energy photon beams.

R Nadrowitz1, T Feyerabend.   

Abstract

If metallic material is exposed to ionizing radiation of sufficient high energy, an increase in dose due to backscatter radiation occurs in front of this material. Our purpose in this study was to quantify these doses at variable distances between scattering materials and the detector at axial beam angles between 0 degree (zero angle in beams eye view) and 90 degrees. Copper, silver and lead sheets embedded in a phantom of perspex were exposed to 10 MV-bremsstrahlung. The detector we developed is based on the fluorescence property of pyromellitic acid (1,2,4,5 benzenetetracarboxylic acid) after exposure to ionizing radiation. Our results show that the additional doses and the corresponding dose distribution in front of the scattering materials depend quantitatively and qualitatively on the beam angle. The backscatter dose increases with varying beam angle from 0 degree to 90 degrees up to a maximum at 55 degrees for copper and silver. At angles of 0 degree and 55 degrees the integral backscatter doses over a tissue-equivalent depth of 2 mm are 11.2% and 21.6% for copper and 24% and 28% for silver, respectively. In contrast, in front of lead there are no obvious differences of the measured backscatter doses at angles between 0 degree and 55 degrees. With a further increase of the beam angle from 55 degrees to 90 degrees the backscatter dose decreases steeply for all three materials. In front of copper a markedly lower penetrating depth of the backscattered electrons was found for an angle of 0 degree compared to 55 degrees. This dependence from the beam angle was less pronounced in front of silver and not detectable in front of lead. In conclusion, the dependence of the backscatter dose from the angle between axial beam and scattering material must be considered, as higher scattering doses have to be considered than previously expected. This may have a clinical impact since the surface of metallic implants is usually curved.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11439492     DOI: 10.1118/1.1366664

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  The effects of the orthopedic metal artifact reduction (O-MAR) algorithm on contouring and dosimetry of head and neck radiotherapy patients.

Authors:  Jussi Sillanpaa; Michael Lovelock; Boris Mueller
Journal:  Med Dosim       Date:  2019-07-30       Impact factor: 1.482

2.  Improvement of dose calculation in radiation therapy due to metal artifact correction using the augmented likelihood image reconstruction.

Authors:  Christian Ziemann; Maik Stille; Florian Cremers; Thorsten M Buzug; Dirk Rades
Journal:  J Appl Clin Med Phys       Date:  2018-04-17       Impact factor: 2.102

3.  Evaluation of the scatter doses in the direction of the buccal mucosa from dental metals.

Authors:  Hiroaki Shimamoto; Iori Sumida; Naoya Kakimoto; Keisuke Marutani; Ryoko Okahata; Ai Usami; Tomomi Tsujimoto; Shumei Murakami; Souhei Furukawa; Sotirios Tetradis
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102

4.  DNA strand breaks based on Monte Carlo simulation in and around the Lipiodol with flattening filter and flattening filter-free photon beams.

Authors:  Daisuke Kawahara; Akito Saito; Hisashi Nakano; Yasushi Nagata
Journal:  Rep Pract Oncol Radiother       Date:  2022-07-29

5.  Effect of dental restorations and prostheses on radiotherapy dose distribution: a Monte Carlo study.

Authors:  David W H Chin; Nathaniel Treister; Bernard Friedland; Robert A Cormack; Roy B Tishler; G Mike Makrigiorgos; Laurence E Court
Journal:  J Appl Clin Med Phys       Date:  2009-02-03       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.