Literature DB >> 11430552

Determination of plasma volume by indocyanine green--validation of the method and use in patients after cardiopulmonary bypass.

S E Menth-Meier1, R Imoberdorf, B Regli, B Kipfer, M Turgay, P E Ballmer.   

Abstract

OBJECTIVE: Validation of plasma volume (PV) determination by indocyanine green (ICG) in comparison to the gold-standard method with radioiodinated albumin, and investigation of the effect of commonly used plasma expanders (albumin, hydroxyethyl starch, and polygelatine) on PV in the early postoperative phase in patients undergoing cardiac surgery.
DESIGN: Prospective clinical study.
SETTING: Department of medicine and intensive care unit at a university hospital. PATIENTS AND PARTICIPANTS: Ten healthy volunteers and 21 patients after elective open-heart surgery. MEASUREMENTS AND
RESULTS: PV of subjects was measured by i.v. injecting 5 microCi [125I]albumin (I-ALB). One hour later, PV was determined by a peripheral i. v. injection of 0.25 mg/kg body weight ICG (ICG1). In five subjects PV was measured repeatedly by ICG (ICG2) 1 h after ICG1. Mean PV of I-ALB and ICG1 or ICG2 showed consistent results. Further, we investigated central vs peripheral intravenous injection of ICG in six patients after open-heart surgery compared to [125I]albumin. There was no difference between mean PV measured by [125I]albumin and peripheral ICG (P = 0.40). PV determined by central injection of ICG was significantly higher than by the other methods. In 15 patients PV was determined by [125I]albumin. Thereafter, patients were randomly divided into three groups. Group ALB was infused with 1.75 ml/kg body weight human albumin 20%, group HAES with 5.25 ml/kg body weight hydroxyethyl starch 6%, and group HAEM with 7.0 ml/kg body weight polygelatine 3.5%. PV was measured 1 h and 4 h after infusion by ICG. There were no significant changes in PV between the groups.
CONCLUSIONS: PV determination by peripheral i. v. injection of ICG produced reliable and consistent results when a reactive hyperaemia was produced by a tourniquet prior to injection. Therefore, central venous injection of ICG may not be prerequisite for precise measurements of PV. The expected acute increase in PV after infusion of commonly used plasma expanders after cardiac surgery was not found.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11430552     DOI: 10.1007/s001340100942

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  6 in total

1.  Haematocrit is invalid for estimating red cell volume: a prospective study in male volunteers.

Authors:  Matthias Jacob; Simon Annaheim; Urs Boutellier; Christian Hinske; Markus Rehm; Christian Breymann; Alexander Krafft
Journal:  Blood Transfus       Date:  2012-05-04       Impact factor: 3.443

2.  Blood Donors on Medication - an Approach to Minimize Drug Burden for Recipients of Blood Products and to Limit Deferral of Donors.

Authors:  Christian D K Becker; Dirk O Stichtenoth; Michael G Wichmann; Christof Schaefer; Ladislaus Szinicz
Journal:  Transfus Med Hemother       Date:  2009-03-13       Impact factor: 3.747

3.  Individualization of the infusion rate of a soybean oil-based intravenous lipid emulsion for inpatients, based on baseline triglyceride concentrations: A population pharmacokinetic approach.

Authors:  Keizo Fukushima; Kenji Omura; Satoshi Goshi; Akira Okada; Motomu Tanaka; Takae Tsujimoto; Keiji Iriyama; Nobuyuki Sugioka
Journal:  JPEN J Parenter Enteral Nutr       Date:  2021-05-12       Impact factor: 3.896

4.  An efficient method for measuring plasma volume using indocyanine green dye.

Authors:  Sixtus Aguree; Alison D Gernand
Journal:  MethodsX       Date:  2019-05-08

Review 5.  How can assessing hemodynamics help to assess volume status?

Authors:  Daniel De Backer; Nadia Aissaoui; Maurizio Cecconi; Michelle S Chew; André Denault; Ludhmila Hajjar; Glenn Hernandez; Antonio Messina; Sheila Nainan Myatra; Marlies Ostermann; Michael R Pinsky; Jean-Louis Teboul; Philippe Vignon; Jean-Louis Vincent; Xavier Monnet
Journal:  Intensive Care Med       Date:  2022-08-10       Impact factor: 41.787

6.  Optimal back-extrapolation method for estimating plasma volume in humans using the indocyanine green dilution method.

Authors:  David Polidori; Clarence Rowley
Journal:  Theor Biol Med Model       Date:  2014-07-22       Impact factor: 2.432

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.