Literature DB >> 11430443

Carotid artery anastomosis with albumin solder and near infrared lasers: a comparative study.

A Lauto1, A H Hamawy, A B Phillips, P B Petratos, J Raman, D Felsen, W Ko, D P Poppas.   

Abstract

BACKGROUND AND
OBJECTIVE: Laser tissue-welding has been used for anastomosis of carotid arteries. During welding, thermal injury sustained by the vessel walls should be minimized to prevent thrombosis. Two different types of lasers were used and effects on tissue damage were studied in vitro and in vivo. STUDY DESIGN/
MATERIALS AND METHODS: End-to-end anastomosis of dog carotid arteries (n = 10) was performed by using a human albumin solder (HAS) in conjunction with Nd:YAG or diode lasers (lambda = 1.32 microm and 1.9 microm, respectively). The arteries were evaluated for patency and evidence of histologic injury after 21 days. Another group of arteries was laser soldered in vitro to measure the intimal and adventitial temperatures by using thermocouples.
RESULTS: The arteries repaired with the diode laser sustained significantly less thermal damage than those repaired with Nd:YAG laser, both in vitro and in vivo. In particular, the intimal temperature was significantly lower (P < 0.05) for the diode than for the Nd:YAG repairs (approximately 35 degrees C and approximately 50 degrees C, respectively). In the latter group, the patency rate was 75%, but thrombosis occurred in 75% of the specimens at 21 days. All diode anastomoses were patent and thrombosis developed in only 17% of the arteries.
CONCLUSION: Use of the diode laser and albumin solders may provide a means to successfully repair carotid arteries with minimal thermal damage.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11430443     DOI: 10.1002/1096-9101(2001)28:1<50::AID-LSM1016>3.0.CO;2-U

Source DB:  PubMed          Journal:  Lasers Surg Med        ISSN: 0196-8092            Impact factor:   4.025


  2 in total

1.  In vivo comparison of near infrared lasers for skin welding.

Authors:  Haşim Ozgür Tabakoğlu; Murat Gülsoy
Journal:  Lasers Med Sci       Date:  2010-05       Impact factor: 3.161

2.  Strong bonding of corneal incisions using a noncontact fiber-optic laser soldering method.

Authors:  Svetlana Basov; David Varssano; Max Platkov; Ilan Gabay; Mordechai Rosner; Irina Barequet; Marcel Rattunde; Joachim Wagner; Mickey Harlev; Doron Ofer; Ilana Nisky; Yair Dankner; Abraham Katzir
Journal:  J Biomed Opt       Date:  2019-12       Impact factor: 3.170