Quantitative detection of Escherichia coli O157 in surface waters by using immunomagnetic electrochemiluminescence.

D R Shelton1, J S Karns.   

Abstract

A protocol for the quantitative detection of Escherichia coli O157 in raw and concentrated surface waters using immunomagnetic electrochemiluminescence (IM-ECL) was developed and optimized. Three antibody sandwich formats were tested: commercial anti-O157:H7 IM beads, IM beads made in-house with a polyclonal anti-O157:H7 immunoglobulin G (IgG), or IM beads made in-house with a monoclonal anti-O157:H7 IgG coupled with a polyclonal anti-O157:H7 IgG to which an electrochemiluminescent label (TAG) was attached. The monoclonal IM bead-polyclonal TAG format was chosen for optimization because it gave lower background levels and linear regression slopes of ca. 1.0, indicative of a constant ECL signal per cell. The dynamic range was ca. 10(1) to 10(5) cells ml(-1) in phosphate-buffered saline and in raw water samples. The monoclonal IM beads selectively captured E. coli O157 cells in the presence of ca. 10(8) cells of a non-O157 strain of E. coli ml(-1). Background ECL signals from concentrated (100-fold) water samples were substantially higher and more variable than raw water samples. The background signal was partially eliminated by the addition of polyvinylpolypyrrolidone. Successive cell capture incubations, termed sequential bead capture (SBC), were optimized for establishing baseline ECL values for individual water samples. The linear dynamic range with SBC was ca. 10(2) to 10(5) E. coli O157 cells ml of concentrated water(-1). To validate the protocol, 10-liter surface water samples were spiked with ca. 5,000 E. coli O157 (Odwalla) cells and concentrated by vortex filtration, and 1- or 3-ml aliquots were analyzed by IM-ECL. Differential ECL signals (SBC) from 1- and 3-ml samples were statistically significant and were generally consistent with standard curves for these cell concentrations. Enrichments were conducted with aliquots of spiked raw water and concentrated water using EC broth and minimal lactose broth (MLB). All tubes with concentrated water became turbid and gave a positive ECL response for E. coli O157 (>10,000 ECL units); MLB gave a somewhat higher detection rate with spiked raw water. The potential sensitivity of the IM-ECL assay is ca. 25 E. coli O157 cells ml of raw water(-1), 25 cells 100 ml of 100-fold concentrated water(-1), or 1 to 2 viable cells liter(-1) with concentration and enrichment. The IM-ECL assay appears suitable for routine analysis and screening of water samples.

Entities:  

Mesh:

Year:  2001        PMID: 11425701      PMCID: PMC92960          DOI: 10.1128/AEM.67.7.2908-2915.2001

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  21 in total

1.  Genetic subtyping of Escherichia coli O157 isolates from 41 Pacific Northwest USA cattle farms.

Authors:  D H Rice; K M McMenamin; L C Pritchett; D D Hancock; T E Besser
Journal:  Epidemiol Infect       Date:  1999-06       Impact factor: 2.451

2.  Immunoliposome sandwich assay for the detection of Escherichia coli O157:H7.

Authors:  S Park; R A Durst
Journal:  Anal Biochem       Date:  2000-04-10       Impact factor: 3.365

3.  Isolation of Escherichia coli O157:H7 from dairy cattle associated with two cases of haemolytic uraemic syndrome.

Authors:  M L Martin; L D Shipman; J G Wells; M E Potter; K Hedberg; I K Wachsmuth; R V Tauxe; J P Davis; J Arnoldi; J Tilleli
Journal:  Lancet       Date:  1986-11-01       Impact factor: 79.321

4.  Verotoxigenic E coli O157 colonisation of wild deer and range cattle.

Authors:  D H Rice; D D Hancock; T E Besser
Journal:  Vet Rec       Date:  1995-11-11       Impact factor: 2.695

5.  Independent regulation of hexose catabolizing enzymes and glucose transport activity in Pseudomonas aeruginosa.

Authors:  P B Hylemon; P V Phibbs
Journal:  Biochem Biophys Res Commun       Date:  1972-09-05       Impact factor: 3.575

6.  Studies on the growth of Escherichia coli O157:H7 strains at 45.5 degrees C.

Authors:  J Ferenc; J Oliver; R Witkowski; L McLandsborough; R E Levin
Journal:  J Food Prot       Date:  2000-09       Impact factor: 2.077

7.  Flow cytometry for the detection of enterohaemorrhagic Escherichia coli O157:H7 with latex beads sensitized with specific antibody.

Authors:  H Kusunoki; M L Bari; T Kita; S Sugii; T Uemura
Journal:  J Vet Med B Infect Dis Vet Public Health       Date:  2000-09

8.  Immunomagnetic-electrochemiluminescent detection of Escherichia coli O157 and Salmonella typhimurium in foods and environmental water samples.

Authors:  H Yu; J G Bruno
Journal:  Appl Environ Microbiol       Date:  1996-02       Impact factor: 4.792

9.  Hemorrhagic colitis associated with a rare Escherichia coli serotype.

Authors:  L W Riley; R S Remis; S D Helgerson; H B McGee; J G Wells; B R Davis; R J Hebert; E S Olcott; L M Johnson; N T Hargrett; P A Blake; M L Cohen
Journal:  N Engl J Med       Date:  1983-03-24       Impact factor: 91.245

10.  Prevalence of enterohemorrhagic Escherichia coli O157:H7 in a survey of dairy herds.

Authors:  T Zhao; M P Doyle; J Shere; L Garber
Journal:  Appl Environ Microbiol       Date:  1995-04       Impact factor: 4.792

View more
  10 in total

1.  Same-day detection of Escherichia coli O157:H7 from spinach by using electrochemiluminescent and cytometric bead array biosensors.

Authors:  Kelly M Leach; Joyce M Stroot; Daniel V Lim
Journal:  Appl Environ Microbiol       Date:  2010-10-29       Impact factor: 4.792

Review 2.  Current and developing technologies for monitoring agents of bioterrorism and biowarfare.

Authors:  Daniel V Lim; Joyce M Simpson; Elizabeth A Kearns; Marianne F Kramer
Journal:  Clin Microbiol Rev       Date:  2005-10       Impact factor: 26.132

3.  Detection of water-borne E. coli O157 using the integrating waveguide biosensor.

Authors:  Peixuan Zhu; Daniel R Shelton; Jeffrey S Karns; Appavu Sundaram; Shuhong Li; Pete Amstutz; Cha-Mei Tang
Journal:  Biosens Bioelectron       Date:  2005-10-15       Impact factor: 10.618

Review 4.  Recent advances in gold nanoparticle-based lateral flow immunoassay for the detection of bacterial infection.

Authors:  Yachana Gupta; Aditya Sharma Ghrera
Journal:  Arch Microbiol       Date:  2021-06-04       Impact factor: 2.552

5.  Development of an immunomagnetic bead-immunoliposome fluorescence assay for rapid detection of Escherichia coli O157:H7 in aqueous samples and comparison of the assay with a standard microbiological method.

Authors:  Thomas R DeCory; Richard A Durst; Scott J Zimmerman; Linda A Garringer; Gary Paluca; Heleen H DeCory; Richard A Montagna
Journal:  Appl Environ Microbiol       Date:  2005-04       Impact factor: 4.792

6.  Development and application of a loop-mediated isothermal amplification method on rapid detection Escherichia coli O157 strains from food samples.

Authors:  Xihong Zhao; Yanmei Li; Li Wang; Lijun You; Zhenbo Xu; Lin Li; Xiaowei He; Yao Liu; Jihua Wang; Liansheng Yang
Journal:  Mol Biol Rep       Date:  2009-08-15       Impact factor: 2.316

7.  Sensitive detection of Shiga Toxin 2 and some of its variants in environmental samples by a novel immuno-PCR assay.

Authors:  Xiaohua He; Wenyuan Qi; Beatriz Quiñones; Stephanie McMahon; Michael Cooley; Robert E Mandrell
Journal:  Appl Environ Microbiol       Date:  2011-03-25       Impact factor: 4.792

8.  tir- and stx-positive Escherichia coli in stream waters in a metropolitan area.

Authors:  James A Higgins; Kenneth T Belt; Jeffrey S Karns; Jonathan Russell-Anelli; Daniel R Shelton
Journal:  Appl Environ Microbiol       Date:  2005-05       Impact factor: 4.792

9.  Rapid and Specific Enrichment of Culturable Gram Negative Bacteria Using Non-Lethal Copper-Free Click Chemistry Coupled with Magnetic Beads Separation.

Authors:  Emilie Fugier; Audrey Dumont; Annie Malleron; Enora Poquet; Jordi Mas Pons; Aurélie Baron; Boris Vauzeilles; Sam Dukan
Journal:  PLoS One       Date:  2015-06-10       Impact factor: 3.240

10.  Visual Detection of Enterohemorrhagic Escherichia coli O157:H7 Using Loop-Mediated Isothermal Amplification.

Authors:  Reza Ranjbar; Maryam Erfanmanesh; Davoud Afshar; Mohsen Mohammadi; Omar Ghaderi; Ali Haghnazari
Journal:  Electron Physician       Date:  2016-06-25
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.