Literature DB >> 11424961

Near infrared spectrophotometry for the diagnosis of vasculogenic erectile dysfunction.

A L Burnett1, R P Allen, D C Wright, I N Trueheart, B Chance.   

Abstract

A specialized near infrared spectrophotometry instrument for noninvasive, continuous monitoring of the hemodynamic events of erection in the human penis has been developed. Its potential application for the diagnostic evaluation of erectile dysfunction was investigated. Thirty-eight patients and 18 volunteer subjects underwent penile near infrared spectrophotometry using an optical sensor probe with wavelength selectivity for hemoglobin absorption spectra. Penile blood volume changes and their time courses were measured following intracavernous pharmacostimulation in patients and visual sexual stimulation in volunteers. Spectrophotometric results were compared with results obtained simultaneously using color duplex ultrasonography, strain gauge penile circumference monitoring, penile tonometry, and clinical assessments. Spectrophotometric recordings of penile erection showed measurable blood volume changes consistent with the hemodynamic events of this biological function. Blood volume per cent (BV%) increase correlated with clinical ratings of erection quality (P < 0.001), penile rigidity measurements (P < 0.005), and penile circumference increases (P < 0.0001), and it correlated with mean peak systolic velocity measurements when BV% increase was restricted to values less than 50% (P < 0.001). The time to reach half the maximum blood volume change (BV T1) correlated directly with the time to reach half the maximum penile circumference size increase (P < 0.001), whereas BV T4 correlated inversely with mean resistive index measurements only when BV T(1/2) was restricted to values greater than 120 s (P < 0.05). Spectrophotometric criteria consisting of BV % less than 35% and BV T(1/2) greater than 120 s affirmed the diagnosis of severe erectile impairment with a similar degree of accuracy as standard ultrasonographic criteria (P < 0.002). Penile near infrared spectrophotometry is a safe, inexpensive and simply used biomedical optics technique that provides quantitative measurements of the vascular physiology of penile erection and appears to offer clinical utility in the diagnosis of vasculogenic erectile dysfunction.

Entities:  

Mesh:

Year:  2000        PMID: 11424961     DOI: 10.1038/sj.ijir.3900609

Source DB:  PubMed          Journal:  Int J Impot Res        ISSN: 0955-9930            Impact factor:   2.896


  3 in total

1.  Probing penile hemodynamics by using photoplethysmography as objective indicators for male erection quality and sexual function.

Authors:  Yuan-Hung Pong; Yi-Kai Chang; Ching-En Hsu; Po-Cheng Chen; Yu-Chuan Lu; Vincent F S Tsai; Hong-Chiang Chang; Men-Tzung Lo; Chen Lin
Journal:  Sci Rep       Date:  2021-06-08       Impact factor: 4.379

2.  A discrepancy of penile hemodynamics during visual sexual stimulation observed by near-infrared spectroscopy.

Authors:  Evgenii Kim; Songhyun Lee; Zephaniah Phillips; Jae G Kim
Journal:  BMC Urol       Date:  2015-02-21       Impact factor: 2.264

3.  Simultaneous Monitoring of Hemodynamic Response in the Pre-Frontal Cortex and Genital Organ During Sexual Arousal Using Near-Infrared Spectroscopy.

Authors:  Evgenii Kim; Sungchul Kim; Phillips V Zephaniah; Songhyun Lee; Eloise Anguluan; Kwangsung Park; Jae Gwan Kim
Journal:  Sex Med       Date:  2018-06-20       Impact factor: 2.491

  3 in total