Literature DB >> 11422702

Fracture strength of copy-milled and conventional In-Ceram crowns.

J W Hwang1, J H Yang.   

Abstract

The purpose of this study was to compare the fracture resistance of copy-milled and conventional In-Ceram crowns. Four groups of 10 uniform sized all-ceramic anterior crowns were fabricated for this test: (1) In-Ceram Spinell (2) In-Ceram Alumina (3) Celay In-Ceram Spinell, and (4) Celay In-Ceram Alumina crowns. All specimens were cemented on stainless steel master die with resin cement and stored in 37 degrees C water for one day prior to loading into a universal testing machine. Using a steel ball at a crosshead speed of 0.5 mm min-1, the crowns were loaded at 30 degrees C angle until catastrophic failure occurred. Mean fracture strength was analysed and compared. Under the conditions of this study and the materials used, the following conclusions were drawn: 1. The strength of Celay In-Ceram anterior crowns had a slightly higher fracture strength than conventional In-Ceram crowns. 2. In-Ceram Alumina crowns had a significantly higher fracture strength than In-Ceram Spinell crowns in both conventional and copy milling methods.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11422702     DOI: 10.1046/j.1365-2842.2001.00731.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  4 in total

1.  Influence of the supporting die structures on the fracture strength of all-ceramic materials.

Authors:  Munir Tolga Yucel; Isa Yondem; Filiz Aykent; Oğuz Eraslan
Journal:  Clin Oral Investig       Date:  2011-08-16       Impact factor: 3.573

2.  Evaluation of the bond strength of resin cements used to lute ceramics on laser-etched dentin.

Authors:  Figen Eren Giray; Lale Duzdar; Mustafa Oksuz; Ilknur Tanboga
Journal:  Photomed Laser Surg       Date:  2014-07       Impact factor: 2.796

3.  A study on the fracture strength of collarless metal-ceramic fixed partial dentures.

Authors:  Jong-Wook Yoon; Sung-Hun Kim; Jai-Bong Lee; Jung-Suk Han; Jae-Ho Yang
Journal:  J Adv Prosthodont       Date:  2010-12-31       Impact factor: 1.904

4.  Influence of Intra-Oral Scanner (I.O.S.) on The Marginal Accuracy of CAD/CAM Single Crowns.

Authors:  Francesco Ferrini; Gianpaolo Sannino; Carlo Chiola; Paolo Capparé; Giorgio Gastaldi; Enrico Felice Gherlone
Journal:  Int J Environ Res Public Health       Date:  2019-02-14       Impact factor: 3.390

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.