Literature DB >> 11419740

Comparison between liquid chromatography-time of-flight mass spectrometry and selected reaction monitoring liquid chromatography-mass spectrometry for quantitative determination of idoxifene in human plasma.

H Zhang1, J Henion.   

Abstract

This study compares HPLC electrospray time-of-flight mass spectrometry and selected reaction monitoring (SRM) LC-MS for high throughput quantitative determination of a small molecule drug in biological samples. A high throughput LC-MS method was developed for quantitatative determination of idoxifene in human plasma and the evaluation was accomplished with the cross-validation of the developed LC-MS method between the time-of-flight mass spectrometer, and a triple quadrupole mass spectrometer operated in the SRM mode. A simple one-step semi-automated 96-well liquid-liquid extraction procedure was used to prepare 96 samples in approximately 30 min and a rapid gradient was used to shorten the LC run time. Time-of-flight mass spectrometry provides acquisition of full-scan mass spectra and extracted ion current chromatograms, which may be extracted from the total ion current chromatogram for peak area determination. The limit of quantitation for idoxifene in human plasma obtained with the time-of-flight mass spectrometer was 5 ng/ml based on 100-microl aliquots of human plasma, and the linear dynamic range was from 5 ng/ml to 2000 ng/ml. The quantitative LC-MS results from the time-of-flight mass spectrometer demonstrated that precision did not exceed 7.1% and accuracy did not exceed 1.7% with reference to quality control samples at three concentration levels in replicates of six. In contrast, the limit of quantitation for idoxifene in human plasma using a tandem triple quadrupole mass spectrometer was 0.5 ng/ml with a linear dynamic range to 1000 ng/ml. The results from the triple quadrupole instrument show that the precision did not exceed 2.2% and accuracy did not exceed 2.9%. The overall results suggest time-of-flight mass spectrometry may be a viable technique for high throughput bioanalytical work for the quantitative determination of a representative small molecule drug in the low ng/ml range in human plasma.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11419740     DOI: 10.1016/s0378-4347(01)00132-3

Source DB:  PubMed          Journal:  J Chromatogr B Biomed Sci Appl        ISSN: 1387-2273


  4 in total

1.  Validation of LC-TOF-MS screening for drugs, metabolites, and collateral compounds in forensic toxicology specimens.

Authors:  Fessessework Guale; Shahriar Shahreza; Jeffrey P Walterscheid; Hsin-Hung Chen; Crystal Arndt; Anna T Kelly; Ashraf Mozayani
Journal:  J Anal Toxicol       Date:  2012-11-01       Impact factor: 3.367

2.  Targeted proteomics: a bridge between discovery and validation.

Authors:  Robert Harlan; Hui Zhang
Journal:  Expert Rev Proteomics       Date:  2014-10-28       Impact factor: 3.940

3.  An Accurate and Effective Method for Measuring Osimertinib by UPLC-TOF-MS and Its Pharmacokinetic Study in Rats.

Authors:  Song-Tao Dong; Ying Li; Hao-Tian Yang; Yin Wu; Ya-Jing Li; Cong-Yang Ding; Lu Meng; Zhan-Jun Dong; Yuan Zhang
Journal:  Molecules       Date:  2018-11-06       Impact factor: 4.411

4.  Neural processes underlying the"same"-"different" judgment of two simultaneously presented objects--an EEG study.

Authors:  Ruiling Zhang; Zhonghua Hu; Debi Roberson; Roberson Debi; Lingcong Zhang; Hong Li; Qiang Liu
Journal:  PLoS One       Date:  2013-12-12       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.