Literature DB >> 11413395

Computerized corneal topography and its importance to wavefront technology.

S E Wilson1, R Ambrosio.   

Abstract

PURPOSE: To review the development and application of corneal topography in refractive surgery.
METHODS: Review of the literature and discussion of recent developments in corneal topography and wavefront technology.
RESULTS: Analysis of corneal topography provides critical information for the preoperative examination of patients before refractive surgery and for the evaluation and treatment of patients with complications after surgery.
CONCLUSIONS: Corneal topography will continue to be a critical diagnostic modality for refractive surgery. Even with the advent of wavefront analysis designed to detect refractive error and aberrations of the eye, it will be necessary to have detailed corneal topographic information to understand the contribution the cornea makes to vision so that custom alteration of that surface can be used to optimize vision. This will be true of the normal eye, but it will be of special importance in eyes with abnormalities that were induced by corneal surgery.

Entities:  

Mesh:

Year:  2001        PMID: 11413395     DOI: 10.1097/00003226-200107000-00001

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  10 in total

Review 1.  [Wavefront analysis and adaptive optics].

Authors:  J D Stevens; W Sekundo
Journal:  Ophthalmologe       Date:  2003-06-17       Impact factor: 1.059

2.  Evaluation of topographic, tomographic, topometric, densitometric, and aberrometric features of cornea with pentacam HR system in subclinical keratoconus.

Authors:  Haci Hasan Ozkan; Mustafa Koc; Hasan Kiziltoprak; Kemal Tekin; Emre Aydemir
Journal:  Int Ophthalmol       Date:  2021-03-27       Impact factor: 2.031

3.  Relation of Corneal Astigmatism with Various Corneal Image Quality Parameters in a Large Cohort of Naïve Corneas.

Authors:  Mohamed Omar Yousif; Rania Serag Elkitkat; Noha Abdelsadek Alaarag; Abdelrhman Shams; Hesham Mohamed Gharieb
Journal:  Clin Ophthalmol       Date:  2020-08-04

4.  Comparison of keratometric and pachymetric parameters with Scheimpflug imaging in normal and keratoconic Asian eyes.

Authors:  Hou-Boon Lim; Gavin S Tan; Li Lim; Hla Myint Htoon
Journal:  Clin Ophthalmol       Date:  2014-11-12

5.  Corneal Biomechanics in Ectatic Diseases: Refractive Surgery Implications.

Authors:  Renato Ambrósio; Fernando Faria Correia; Bernardo Lopes; Marcella Q Salomão; Allan Luz; Daniel G Dawson; Ahmed Elsheikh; Riccardo Vinciguerra; Paolo Vinciguerra; Cynthia J Roberts
Journal:  Open Ophthalmol J       Date:  2017-07-31

Review 6.  Pentacam® Corneal Tomography for Screening of Refractive Surgery Candidates: A Review of the Literature, Part I.

Authors:  Mahsaw N Motlagh; Majid Moshirfar; Michael S Murri; David F Skanchy; Hamed Momeni-Moghaddam; Yasmyne C Ronquillo; Phillip C Hoopes
Journal:  Med Hypothesis Discov Innov Ophthalmol       Date:  2019

7.  Multimodal imaging for refractive surgery: Quo vadis?

Authors:  Renato Ambrósio
Journal:  Indian J Ophthalmol       Date:  2020-12       Impact factor: 1.848

8.  Corneal biomechanics for corneal ectasia: Update.

Authors:  Louise P G Esporcatte; Marcella Q Salomão; Nelson S Junior; Aydano P Machado; Érica Ferreira; Tomás Loureiro; Renato A Junior
Journal:  Saudi J Ophthalmol       Date:  2022-07-11

Review 9.  Dynamic corneal deformation response and integrated corneal tomography.

Authors:  Marcella Q Salomão; Ana Luisa Hofling-Lima; Fernando Faria-Correia; Bernardo Teixeira Lopes; Sandra Rodrigues-Barros; Cynthia J Roberts; Renato Ambrósio
Journal:  Indian J Ophthalmol       Date:  2018-03       Impact factor: 1.848

10.  The Role of Corneal Biomechanics for the Evaluation of Ectasia Patients.

Authors:  Marcella Q Salomão; Ana Luisa Hofling-Lima; Louise Pellegrino Gomes Esporcatte; Bernardo Lopes; Riccardo Vinciguerra; Paolo Vinciguerra; Jens Bühren; Nelson Sena; Guilherme Simões Luz Hilgert; Renato Ambrósio
Journal:  Int J Environ Res Public Health       Date:  2020-03-23       Impact factor: 3.390

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.