Literature DB >> 11408444

Dynamic effects of positive-pressure ventilation on canine left ventricular pressure-volume relations.

A Y Denault1, J Gorcsan, M R Pinsky.   

Abstract

Positive-pressure ventilation (PPV) may affect left ventricular (LV) performance by altering both LV diastolic compliance and pericardial pressure (Ppc). We measured the effect of PPV on LV intraluminal pressure, Ppc, LV volume, and LV cross-sectional area in 17 acute anesthetized dogs. To account for changes in lung volume independent of changes in Ppc and differences in contractility, measures were made during both open- and closed-chest conditions, during closed chest with and without chest wall binding, and after propranolol-induced acute ventricular failure (AVF). Apneic end-systolic pressure-volume relations (ESPVR) were generated by inferior vena caval occlusions. With the open chest, PPV had no effects. With the chest closed, PPV inspiration decreased LV end-diastolic volume (EDV) along its diastolic compliance curve and decreased end-systolic volume (ESV) such that the end-systolic pressure-volume domain was shifted to a point left of the LV ESPVR, even when referenced to Ppc. The decrease in EDV was greater in control than in AVF conditions, whereas the shift of the ESV to the left of the ESPVR was greater with AVF than in control conditions. We conclude that the hemodynamic effects of PPV inspiration are due primarily to changes in intrathoracic pressure and that the inspiration-induced decreases of LV EDV reflect direct effects of intrathoracic pressure on LV filling. The decreases in LV ESV exceed the amount explained solely by a reduction in LV ejection pressure.

Entities:  

Mesh:

Year:  2001        PMID: 11408444     DOI: 10.1152/jappl.2001.91.1.298

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  5 in total

1.  Influence of respiratory pressure support on hemodynamics and exercise tolerance in patients with COPD.

Authors:  Cristino Carneiro Oliveira; Cláudia Regina Carrascosa; Audrey Borghi-Silva; Danilo C Berton; Fernando Queiroga; Eloara M V Ferreira; Luiz E Nery; J Alberto Neder; J Alberto Neder
Journal:  Eur J Appl Physiol       Date:  2010-03-06       Impact factor: 3.078

Review 2.  Basics of monitoring equipment.

Authors:  Tanya Duke-Novakovski
Journal:  Can Vet J       Date:  2017-11       Impact factor: 1.008

3.  Estimating left ventricular contractility using inspiratory-hold maneuvers.

Authors:  Hyung Kook Kim; Mohammed T Alhammouri; Yasser M Mokhtar; Michael R Pinsky
Journal:  Intensive Care Med       Date:  2006-11-14       Impact factor: 17.440

4.  A robust Fourier-based method to measure pulse pressure variability.

Authors:  Sebastian Acosta; Mubbasheer Ahmed; Suellen M Yin; Ken M Brady; Daniel J Penny; Craig G Rusin
Journal:  Biomed Signal Process Control       Date:  2020-04-17       Impact factor: 3.880

5.  The Safety and Efficacy of Inspiratory Muscle Training for Patients With Acute Myocardial Infarction Undergoing Percutaneous Coronary Intervention: Study Protocol for a Randomized Controlled Trial.

Authors:  YuanHui Liu; YiNing Dai; Zhi Liu; HuiMin Zhan; Manyu Zhu; XianYuan Chen; ShengQing Zhang; GuoLin Zhang; Ling Xue; ChongYang Duan; JiYan Chen; Lan Guo; PengCheng He; Ning Tan
Journal:  Front Cardiovasc Med       Date:  2021-01-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.