Literature DB >> 11406793

In vitro comparison of the fracture resistance and failure mode of fiber, ceramic, and conventional post systems at various stages of restoration.

C J Cormier1, D R Burns, P Moon.   

Abstract

PURPOSE: This in vitro study evaluated 6 post systems over 4 simulated clinical stages of tooth restoration to (1) determine quantitatively the fracture resistance strength at each stage when a static loading force is applied to cause failure; (2) determine the failure mode for each post system at each simulated clinical stage; and (3) determine the feasibility of removing failed post systems.
MATERIALS AND METHODS: Ten post systems made with various materials and designs were tested at the following 4 stages of simulated clinical treatment: stage #1: posts only, loaded using a 3-point loading model to failure, to determine transverse strengths and failure modes for each post system; stage #2: posts alone, bonded into teeth; stage #3: posts bonded into teeth with core build up; stage #4: post and core build up and full veneer restoration. For stages #2 through #4, the coronal portion of 60 mandibular premolars was amputated at the cemento-enamel junction, the canals were treated endodontically, and the specimens were mounted in acrylic blocks. A testing force was applied to the posts at 90 degrees to the long axis of the tooth, 4 mm from the cemento-enamel junction. The O'Brien test for constant variance was performed over the treatment groups. For nonconstant variance, the Welsh analysis of variance was used to test for equalities of treatment means. The Tukey Kramer procedure determined which treatment procedures differed.
RESULTS: The failure thresholds for each post system were significantly different at each stage of testing, but the order of test results by post type remained generally consistent from one stage to the next. ParaPosts (Coltene, Whaledent Int, New York, NY) and core build up resulted in significantly higher failure thresholds through all 4 stages of testing. This post system also consistently displayed a high number of nonfavorable tooth fractures. FibreKor post and cores (Jeneric Pentron Inc, Wallingford, CT) resulted in significantly lower failure threshold values in stages #2 through #4. This post system displayed no tooth fractures in stages #2 and #3 and a similar number of nonfavorable tooth fractures in stage #4 when compared with the other systems. C-Post (Bisco Dental Products, Schaumburg, IL), CosmoPost (Ivoclar Vivadent North America Inc, Amherst, NY), and AesthetiPost (Bisco Dental Products) grouped in descending order through stages #2 to #4. These systems displayed intermediate fracture resistance strengths, as well as a moderate number of nonfavorable tooth fractures. CosmoPost exhibited a significant number of brittle post fractures with fragments left in the root canal at all stages. The fracture resistance of the cast metal post varied from stage to stage. No teeth fractured at stage #2. At stage #3, 9 of 10 teeth fractured nonfavorably, and all teeth fractured nonfavorably in stage #4.
CONCLUSIONS: The fiber posts evaluated provided an advantage over a conventional post that showed a higher number of irretrievable post and unrestorable root fractures. At the stage of final restoration insertion, there was no difference in force to failure for all but the FibreKor material, which continued to be weaker than all other tested materials. The fiber posts were readily retrievable after failure, whereas the remaining post systems tested were nonretrievable. J Prosthodont 2001;10:26-36. Copyright 2001 by The American College of Prosthodontists.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11406793     DOI: 10.1111/j.1532-849x.2001.00026.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  18 in total

1.  Enhanced aesthetics with metal-free ceramics and post systems-case reports.

Authors:  Manjit Kumar; M Viswambaran; Prashant Awasthi; Tarun Dabra
Journal:  Med J Armed Forces India       Date:  2012-04-21

2.  Analysis of fracture resistance of endodontically treated teeth restored with different post and core system of variable diameters: an in vitro study.

Authors:  S I Joephin Soundar; T J Suneetha; Mano Christaine Angelo; Lin Cherian Kovoor
Journal:  J Indian Prosthodont Soc       Date:  2014-01-26

3.  All about Dowels - A Review Part I. Considerations before Cementation.

Authors:  Zishan Dangra; Mahesh Gandhewar
Journal:  J Clin Diagn Res       Date:  2017-08-01

4.  Fracture Resistance of Endodontically Treated Roots Restored with Fiber Posts Using Different Resin Cements- An In-vitro Study.

Authors:  Swetha Gopal; Sujatha Irodi; Deepak Mehta; Shankar Subramanya; Vinay Kumar Govindaraju
Journal:  J Clin Diagn Res       Date:  2017-02-01

5.  In vitro evaluation of glass fiber post.

Authors:  Jasjit Kaur; Navneet Sharma; Harpal Singh
Journal:  J Clin Exp Dent       Date:  2012-10-01

6.  A comparative evaluation of the fracture resistance of three different pre-fabricated posts in endodontically treated teeth: An in vitro study.

Authors:  Prabeesh Padmanabhan
Journal:  J Conserv Dent       Date:  2010-07

7.  Influence of different restorative techniques on the strength of endodontically treated weakened roots.

Authors:  Khalid H Alsamadani; El-Sayed Mohammed Abdaziz; El-Sayed Gad
Journal:  Int J Dent       Date:  2012-05-14

8.  An ex vivo comparative study on the retention of custom and prefabricated posts.

Authors:  Abhinav Singh; Ajay Logani; Naseem Shah
Journal:  J Conserv Dent       Date:  2012-04

9.  Fracture resistance of upper central incisors restored with different posts and cores.

Authors:  Maryam Rezaei Dastjerdi; Kamran Amirian Chaijan; Saeid Tavanafar
Journal:  Restor Dent Endod       Date:  2015-07-24

10.  Finite element analysis of adhesive endo-crowns of molars at different height levels of buccally applied load.

Authors:  Istabrak Hasan; Matthias Frentzen; Karl-Heinz Utz; Daniel Hoyer; Alexander Langenbach; Christoph Bourauel
Journal:  J Dent Biomech       Date:  2012-08-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.